Skip to main content

Advertisement

Log in

Comparing whole body 18F-2-deoxyglucose positron emission tomography and technetium-99m methylene diphosphate bone scan to detect bone metastases in patients with renal cell carcinomas – a preliminary report

  • Original Paper
  • Published:
Journal of Cancer Research and Clinical Oncology Aims and scope Submit manuscript

Abstract

Purpose. Conventional technetium-99m methylene diphosphate whole body bone scan (bone scan) has a high sensitivity but a poor specificity to detect bone metastases. However, positron emission tomography with 18F-2-deoxyglucose (FDG-PET) can offer superior spatial resolution and improved specificity. We have attempted to evaluate the usefulness of FDG-PET for detecting bone metastases in renal cell carcinomas (RCC) and to compare FDG-PET results with bone scan findings.

Methods. Eighteen patients were selected for this study with biopsy-proven RCC. They were suspected of having bone metastases and were undergoing bone scan and FDG-PET to detect bone metastases. The final diagnoses of bone metastases were established by operative, histopathological findings or clinical follow-up longer than 1 year by additional radiographs or following FDG-PET/bone scan findings showing progressive and extensive widespread bone lesions.

Results. A total of 52 bone lesions including 40 metastatic and 12 benign bone lesions found on either FDG-PET or bone scan were evaluated. FDG-PET could accurately diagnose all 40 metastatic and 12 benign bone lesions. Bone scan could accurately diagnose only 31 metastatic bone lesions. Diagnostic sensitivity and accuracy of FDG-PET were 100% and 100%, respectively,and bone scan were 77.5% and 59.6%, respectively.

Conclusions. Our data suggest that FDG-PET has a higher sensitivity and a better accuracy than that of bone scan to detect bone metastases in patients with RCC.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wu, .H., Yen, .R., Shen, .Y. et al. Comparing whole body 18F-2-deoxyglucose positron emission tomography and technetium-99m methylene diphosphate bone scan to detect bone metastases in patients with renal cell carcinomas – a preliminary report. J Cancer Res Clin Oncol 128, 503–506 (2002). https://doi.org/10.1007/s00432-002-0370-1

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00432-002-0370-1

Navigation