Skip to main content

Advertisement

Log in

Comparison of pharmacokinetic MRI and [18F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

  • Breast
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[18F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brix, G., Henze, M., Knopp, M.V. et al. Comparison of pharmacokinetic MRI and [18F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience. Eur Radiol 11, 2058–2070 (2001). https://doi.org/10.1007/s003300100944

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300100944

Navigation