Skip to main content

Advertisement

Log in

The impact of FDG-PET on the management algorithm for recurrent colorectal cancer

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Positron emission tomography (PET) has been successfully used to image colorectal cancer (CRC). This study evaluated the accuracy of 2-[18F]-fluoro-2-deoxy-D-glucose (FDG) PET for the detection and staging of recurrent CRC and the consequent impact on clinical management. Forty-two patients previously treated for CRC were investigated for suspected recurrence and, if recurrence was confirmed, the extent of disease was evaluated. All patients underwent whole-body FDG-PET and computed tomography (CT) scan and results were compared to assess sensitivity, specificity and diagnostic accuracy for each modality. We then assessed the FDG-PET directed alteration in clinical management from that planned on the basis of spiral CT results. FDG-PET was more sensitive (93%) than CT (73%) for detection of recurrence (specificity 58% and 75%, respectively). FDG-PET yielded a correct diagnosis in 35 (83%) out of 42 patients, while CT did so in 31 patients (74%). FDG-PET was more accurate than CT for staging local recurrence (sensitivity 100%, specificity 86% with FDG-PET vs 75% and 100%, respectively, with CT) and CRC liver metastases (sensitivity 100% vs 45%; specificity 100% for both). Overall, PET upstaged 8 out of 30 patients (27%) and altered patient management in 16 (38%) cases. This study confirms that FDG-PET is more sensitive than CT for the detection and staging of recurrent CRC. The results also indicate that FDG-PET is an accurate means of selecting appropriate patients for operative treatment. When applied to routine clinical practice, patient management is altered.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 2 July and in revised form 17 August 2001

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Arulampalam, T., Costa, D., Visvikis, D. et al. The impact of FDG-PET on the management algorithm for recurrent colorectal cancer. Eur J Nucl Med 28, 1758–1765 (2001). https://doi.org/10.1007/s002590100646

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590100646

Navigation