Skip to main content

Advertisement

Log in

Iterative reconstruction: an improvement of technetium-99m MIBI SPET for the detection of parathyroid adenomas?

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

The purpose of this study was to assess the value of technetium-99m methoxyisobutylisonitrile (MIBI) single-photon emission tomography (SPET) and an iterative reconstruction algorithm for the preoperative localisation of parathyroid adenomas (PTAs). Seventy-two patients (26 male, 46 female, mean age 58±16 years) with known primary hyperparathyroidism were examined preoperatively. First, a thyroid examination was performed to detect possible MIBI-accumulating thyroid lesions. Planar scans were then acquired 15 and 120 min and tomographic images 120 min after intravenous injection of 740 MBq 99mTc-MIBI, using a triple-head gamma camera (Picker Prism 3000). Additionally, 99mTc-MIBI/ 99mTc-pertechnetate subtraction scintigraphy of the early planar images was performed. The SPET data were evaluated using an iterative reconstruction (multiplicative iterative SPET reconstruction: MISR) as well as a standard algorithm (FBP: filtered back-projection with application of a 3-D low-pass postfilter). The weight of the resected PTAs ranged from 110 mg to 5 g. Using planar MIBI scans, correct localisation of the side of the PTA was possible in 81% of cases (58% for PTAs weighing less than 500 mg). Sensitivity increased to 94% using SPET and FBP, while with MISR it rose further, to 97%. Patients with PTAs weighing less than 500 mg showed a sensitivity of 88% with MISR and 81% with FBP. Furthermore, there was a clear improvement in image quality using MISR. None of the normal parathyroid glands were visualised. This study indicates that, in comparison with planar scintigraphy, 99mTc-MIBI SPET is a more sensitive and specific tool for topographical localisation of PTAs, especially those that are small. There is a further improvement in sensitivity and image quality when iterative reconstruction is used instead of FBP.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 8 August 1999 and in revised form 20 January 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Moka, D., Eschner, W., Voth, E. et al. Iterative reconstruction: an improvement of technetium-99m MIBI SPET for the detection of parathyroid adenomas?. Eur J Nucl Med 27, 485–489 (2000). https://doi.org/10.1007/s002590050532

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050532

Navigation