Skip to main content
Log in

Dual-head gamma camera 2-[fluorine-18]-fluoro-2-deoxy-d-glucose positron emission tomography in oncological patients: effects of non-uniform attenuation correction on lesion detection

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

The purpose of this study was to evaluate a dual head coincidence gamma camera (DH-PET) equipped with single-photon transmission for 2-[fluorine-18]-fluoro-2-deoxy-d-glucose (FDG) imaging in oncological patients. Forty-five patients with known or suspected malignancies, scheduled for a positron emission tomography (PET) scan, were first studied with a dedicated ring PET and subsequently with DH-PET. All patients underwent measured attenuation correction using germanium-68 rod sources for ring PET and caesium-137 sources for DH-PET. Ring PET emission scan was started 64±17 min after intravenous administration of 235±42 MBq FDG. DH-PET emission followed 160±32 min after i.v. FDG. Attenuation-corrected and non-attenuation-corrected images were reconstructed for ring PET and DH-PET. The image sets were evaluated independently by three observers blinded to clinical data and to results of conventional imaging. Attenuation-corrected ring PET as the standard of reference depicted 118 lesions, non-attenuation-corrected ring PET 113 (96%) lesions, and attenuation-corrected DH-PET and non-attenuation-corrected DH-PET, 101 (86%) and 84 (71%) lesions, respectively (P<0.05). The lesion detection rate of attenuation-corrected and non-attenuation-corrected DH-PET was almost similar for lesions >20 mm, whereas attenuation correction increased the detection rate from 60% to 80% for lesions ≤20 mm (P<0.01). A patient-based analysis revealed concordant results relative to attenuation-corrected ring PET for non-attenuation-corrected ring PET, attenuation-corrected DH-PET and non-attenuation-corrected DH-PET in 42 (93%), 36 (80%) and 31 (69%) patients, respectively. Differences might have influenced patient management in two (4%), six (13%) and ten (22%) patients, respectively. In conclusion, measured attenuation correction markedly improves the lesion detection capability of DH-PET. With measured attenuation correction the diagnostic performance of DH-PET is closer to that of dedicated ring PET.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 9 April and in revised form 20 April 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zimny, M., Kaiser, H., Cremerius, U. et al. Dual-head gamma camera 2-[fluorine-18]-fluoro-2-deoxy-d-glucose positron emission tomography in oncological patients: effects of non-uniform attenuation correction on lesion detection. Eur J Nucl Med 26, 818–823 (1999). https://doi.org/10.1007/s002590050454

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050454

Navigation