Measurement of lymphatic function with technetium-99m-labelled polyclonal immunoglobulin

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

A reliable method for measuring lymph flow in physiological units would be valuable, especially in conditions in which it is uncertain whether lymph flow is increased or decreased. The requirements of a radiopharmaceutical for such measurement include stable radionuclide labelling and rapid access to lymphatic vessels following tissue injection but no access to blood vessels. A soluble macromolecule is likely to come closest to meeting these requirements. Technetium-99m- labelled human polyclonal immunoglobulin (HIG) was therefore investigated firstly in comparison with 99mTc-labelled human serum albumin (HSA) in patients undergoing routine lymphoscintigraphy and secondly with respect to injection site in a group of volunteers with post-mastectomy oedema (PMO). Subcutaneous injection of 99mTc-HIG into the web space of a distal extremity gave images in which lymphatic vessels were more clearly defined compared with images obtained after injection of 99mTc-HSA. Lymph nodes were also more clearly defined, suggesting specific retention of HIG, possibly through Fc-mediated binding. Peripheral blood sampling showed a delayed arrival in blood of radioactivity after 99mTc-HIG compared with 99mTc-HSA, although ultimately, the blood recovery of 99mTc-HIG was significantly higher (<0.05) than that of 99mTc-HSA. Clearance rates of radioactivity from the injection site were not sinificantly different, however, between the two agents. In patients with PMO, web space injection of 99mTc-HIG gave excellent images of normal lymphatic vessels, of lymph nodes and of abnormal lymph drainage such as dermal backflow in swollen arms. In contrast, neither lymphatic vessels nor lymph nodes were visualised after injection into the skin of the dorsum of the distal forearm. Although there was no difference in clearance rates from the injection sites between normal and swollen arms with either agent in PMO, clearance was significantly faster following injection into the web space (0.11% per minute for normal and swollen arms combined) than into the forearm (0.053% per minute; P<0.05). These results suggest that (a) 99mTc-HIG is a potentially useful agent for measuring lymph flow and lymph node function; but (b) injection into the dorsum of the forearm is not a useful method of administration for these measurements; and (c) clearance rates from the injection site do not support the notion that PMO is the result of decreased lymph flow. Further studies are warranted to evaluate 99mTc-HIG as an agent for assessment of lymphatic function, especially with respect to measurement of lymph flow and possibly also for the evaluation of lymph node Fc-mediated immunocompetence.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 28 July and in revised form 26 October 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Svensson, W., Glass, D., Bradley, D. et al. Measurement of lymphatic function with technetium-99m-labelled polyclonal immunoglobulin. Eur J Nucl Med 26, 504–510 (1999). https://doi.org/10.1007/s002590050418

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050418

Navigation