Skip to main content

Advertisement

Log in

Uptake of positron emission tomography tracers in experimental bacterial infections: a comparative biodistribution study of radiolabeled FDG, thymidine, l-methionine, 67Ga-citrate, and 125I-HSA

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract.

The purpose of this study was to evaluate the localization of positron emission tomography (PET) tracers [2-deoxy-2-fluoro-d-glucose (FDG), thymidine, and l-methionine] in sites of bacterial infection, and to contrast this with that of other tracers. The left calf muscles of rats were infected with a suspension of Escherichia coli and the biodistribution of 18F- or 3H-FDG, 3H-thymidine, l-11C- or 3H-methionine, gallium-67 citrate (67Ga-citrate) and iodine-125 human serum albumin (125I-HSA) was determined in these animals. 3H-FDG uptake in the infectious foci was evaluated by autoradiography of histological sections. Although 18F-FDG, 67Ga-citrate, and 125I-HSA showed comparatively high uptake in the infected muscle [the percentage activity of injected dose (ID) per gram of tissue normalized for rat weight in kilogram (%ID/g)×kg at 2 h postinjection was as follows: 18F-FDG, 0.184±0.026 to 0.218±0.046; 67Ga-citrate, 0.221±0.016; 125I-HSA, 0.198±0.019], the infected muscle to blood ratio was much higher for 18F-FDG than for 67Ga-citrate or 125I-HSA (18F-FDG, 10.31±0.76 to 14.89±2.26; 67Ga-citrate, 1.24±0.67; 125I-HSA, 0.20±0.02). The draining reactive lymph nodes also showed higher accumulation of 18F-FDG than of 67Ga-citrate or 125I-HSA. The uptake of 3H-thymidine and l-11C- or 3H-methionine in the infected muscle was lower than that of 18F- or 3H-FDG (at 2 h postinjection, 3H-thymidine = 0.039±0.005 and L-3H-methionine = 0.063±0.007 (%ID/g)×kg. Autoradiographs showed that the highest 3H-FDG uptake was seen in the area of inflammatory cell infiltration surrounding the necrotic region. In conclusion, 18F-FDG, which rapidly accumulates in sites of bacterial infection and in reactive lymph nodes with a high target to background ratio, appears to be a promising infection detection agent.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 26 September and in revised form 18 December 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sugawara, Y., Gutowski, T., Fisher, S. et al. Uptake of positron emission tomography tracers in experimental bacterial infections: a comparative biodistribution study of radiolabeled FDG, thymidine, l-methionine, 67Ga-citrate, and 125I-HSA. Eur J Nucl Med 26, 333–341 (1999). https://doi.org/10.1007/s002590050395

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050395

Navigation