Skip to main content
Log in

Recovery correction for quantitation in emission tomography: a feasibility study

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

In emission tomography, the spread of regional tracer uptake to surrounding areas caused by limited spatial resolution of the tomograph must be taken into account when quantitating activity concentrations in vivo. Assuming linearity and stationarity, the relationship between imaged activity concentration and true activity concentration is only dependent on the geometric relationship between the limited spatial resolution of the tomograph in all three dimensions and the three-dimensional size and shape of the object. In particular it is independent of the type of object studied. This concept is characterized by the term ”recovery coefficient”. Recovery effects can be corrected for by recovery coefficients determined in a calibration measurement for lesions of simple geometrical shape. This method works on anatomical structures that can be approximated to simple geometrical objects. The aim of this study was to investigate whether recovery correction of appropriate structures is feasible in a clinical setting. Measurements were done on a positron emission tomography (PET) scanner in the 2D and 3D acquisition mode and on an analogue and digital single-photon emission tomography (SPET) system using commercially available software for image reconstruction and correction of absorption and scatter effects. The results of hot spot and cold spot phantom measurements were compared to validate the assumed conditions of linearity and stationarity. It can be concluded that a recovery correction is feasible for PET scanners down to lesions measuring about 1.5×FWHM in size, whereas with simple correction schemes, which are widely available, an object-independent recovery correction for SPET cannot be performed. This result can be attributed to imperfections in the commercially available methods for attenuation and scatter correction in SPET, which are only approximate.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 22 June and in revised form 30 September 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Geworski, L., Knoop, B., de Cabrejas, M. et al. Recovery correction for quantitation in emission tomography: a feasibility study. Eur J Nucl Med 27, 161–169 (2000). https://doi.org/10.1007/s002590050022

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050022

Navigation