Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers

  • Original Paper
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

Although non-uniform attenuation correction (NUAC) can supply more accurate absolute quantification, it is not entirely clear whether NUAC provides clear-cut benefits in the routine clinical practice of brain SPET imaging. The aim of this study was to compare the effect of NUAC versus uniform attenuation correction (UAC) on volume of interest (VOI)-based semi-quantification of a large age- and gender-stratified brain perfusion normal database. Eighty-nine healthy volunteers (46 females and 43 males, aged 20–81 years) underwent standardised high-resolution single-photon emission tomography (SPET) with 925 MBq 99mTc-ethyl cysteinate dimer (ECD) on a Toshiba GCA-9300A camera with 153Gd or 99mTc transmission CT scanning. Emission images were reconstructed by filtered back-projection and scatter corrected using the triple-energy window correction method. Both non-uniform Chang attenuation correction (one iteration) and uniform Sorenson correction (attenuation coefficient 0.09 cm–1) were applied. Images were automatically re-oriented to a stereotactic template on which 35 predefined VOIs were defined for semi-quantification (normalisation on total VOI counts). Small but significant differences between relative VOI uptake values for NUAC versus UAC in the infratentorial region were found. VOI standard deviations were significantly smaller for UAC, 4.5% (range 2.6–7.5), than for NUAC, 5.0% (2.3–9.0) (P<0.01). Higher filter roll-off values of the transmission reconstruction filter increased noise in the emission images and altered estimated cortical attenuation coefficients as well as uptake values. In conclusion, semi-quantification based upon reconstruction with UAC results in very similar 99mTc-ECD uptake values in healthy volunteers to those obtained with NUAC, although values for the infratentorial region are slightly lower. NUAC produces a slight increase in inter-subject variability. Further study is necessary in various patient populations to establish the full clinical impact of NUAC in brain perfusion SPET.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 28 July and in revised form 22 September 2000

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Van Laere, K., Koole, M., Versijpt, J. et al. Non-uniform versus uniform attenuation correction in brain perfusion SPET of healthy volunteers. Eur J Nucl Med 28, 90–98 (2001). https://doi.org/10.1007/s002590000407

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590000407

Navigation