Skip to main content
Log in

Simplified quantification of dopamine transporters in humans using [99mTc]TRODAT-1 and single-photon emission tomography

  • Short Communication
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

Quantification of dopamine transporters (DAT) using [99mTc]TRODAT-1 and single-photon emission tomography (SPET) requires full kinetic modeling of the data, using complex and invasive arterial blood sampling to provide an input function to the model. We have shown previously that a simpler reference tissue model provides accurate quantitative results, using a reference region devoid of DAT as the input to the model and thereby obviating the need for blood sampling. We now extend this work into humans, and develop further simplifications to make the imaging protocol much more practical as a routine procedure. Fourteen healthy subjects (age 29.8±8.4 years, range 18.7–45.5 years) underwent dynamic SPET for 6 h following injection of 752±28 MBq [99mTc]TRODAT-1. The kinetic data were analyzed using nonlinear regression analysis (NLRA) and Logan-Patlak graphical analysis. In addition, simple average ratios of striatal-to-background counts were obtained for three 1-h periods (3–4 h, 4–5 h, 5–6 h), and compared against the kinetic models. All methods gave an index of specific binding, proportional to the binding potential, known as the distribution volume ratio (DVR). The reference tissue NLRA gave mean values of k 3=0.013±0.003 min–1, k 4=0.011±0.002 min–1, and DVR=2.29±0.17. Graphical analysis gave a value of DVR=2.28±0.16, and the three ratio values of DVR were: 3–4 h, 2.18±0.15; 4–5 h, 2.34±0.13; and 5–6 h, 2.46±0.19. Graphical analysis was highly correlated with NLRA (R 2=0.91, slope=0.90±0.08). The ratio methods correlated well with NLRA (3–4 h, R 2=0.71, slope=0.73±0.13; 4–5 h, R 2=0.86, slope=0.73±0.09; 5–6 h, R 2=0.80, slope=1.00±0.15), and also with graphical analysis (3–4 h, R 2=0.65, slope=0.74±0.16; 4–5 h, R 2=0.85, slope=0.78±0.09; 5–6 h, R 2=0.88, slope=1.11±0.12). The optimum equilibrium time point for obtaining a simple ratio was approximately 4.5–5.5 h. In conclusion, the simple ratio techniques for obtaining a quantitative measure of specific binding correlated well with the reference tissue kinetic models, using both NLRA and graphical analysis. The optimum time for obtaining a ratio appeared to be in the range 4.5–5.5 h. Earlier time points, while still relatively accurate, had a lower sensitivity and may not be optimized for measuring small changes in DAT concentrations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Additional information

Received 18 April and in revised form 28 July 2000

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Acton, P., Meyer, P., Mozley, P. et al. Simplified quantification of dopamine transporters in humans using [99mTc]TRODAT-1 and single-photon emission tomography. Eur J Nucl Med 27, 1714–1718 (2000). https://doi.org/10.1007/s002590000371

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590000371

Navigation