Abstract
Purpose
The diagnosis of infection is often based on clinical, pathological and microbiological results. However, these investigations lack specificity. White blood cell (WBC) scintigraphy is considered the gold standard nuclear imaging technique for diagnosing infections in bone and soft tissues (except spondylodiscitis). However, image acquisition and interpretation criteria differ amongst centres throughout the world, leading to differences in reported results. The aim of this study was to identify the most accurate WBC scintigraphy acquisition and interpretation protocols for diagnosis of bone and soft tissue infections.
Methods
Included in this retrospective study were 297 patients with suspected bone or soft tissue infection who underwent WBC scintigraphy with 99mTc-HMPAO-labelled leucocytes between 2009 and 2012. Sensitivity, specificity, accuracy, and positive and negative predictive values of WBC scintigraphy were determined for two different dual time point acquisition protocols (fixed-time acquisition and time decay-corrected acquisition) and five image interpretation methods (visual and semiquantitative with four different reference regions of interest). Final diagnosis was based on pathological and microbiological reports, and when these were not available, on clinical follow-up of at least 6 months.
Results
The best acquisition protocol was 4 h and 20 – 24 h dual time-point acquisition with time decay-corrected acquisition. When using this acquisition protocol, visual qualitative interpretation led to a sensitivity of 85.1 %, a specificity of 97.1 %, a diagnostic accuracy of 94.5 %, a positive predictive value of 88.8 % and a negative predictive value of 95.9 %. For semiquantitative analysis, the best results were found when lesion-to-reference ratios were calculated with the contralateral side as the reference tissue, except for osteomyelitis and infected osteosynthesis, for which the contralateral bone marrow was found to be the best reference tissue. Results of the semiquantitative analyses per se were not better than for visual analysis. In the optimal analysis protocol, scans are first visually evaluated, and if this gives equivocal results, semiquantitative analysis is performed. This strategy resulted in an improved sensitivity of 97.9 %, a specificity of 91.8 % and a diagnostic accuracy of 93.1 %.
Conclusion
WBC scintigraphy for bone and soft-tissue infection is best performed using a dual acquisition protocol at 4 h and at 20–24 h after injection, in which the acquisition time of the scans is corrected for decay. In most patients, visual analysis is sufficient and leads to high diagnostic accuracy. When interpretation by visual analysis is inconclusive, semiquantitative analysis adds accuracy. Based on our results, we propose a flow chart for analysing WBC scintigraphy in musculoskeletal infections.
Similar content being viewed by others
References
Glaudemans AW, Signore A. FDG-PET/CT in infections: the imaging method of choice? Eur J Nucl Med Mol Imaging. 2010;37:1986–91.
Glaudemans AW, Galli F, Pacilio M, Signore A. Leukocyte and bacteria imaging in prosthetic joint infection. Eur Cell Mater. 2013;25:61–77.
Gotthardt M, Bleeker-Rovers CP, Boerman OC, Oyen WJ. Imaging of inflammation by PET, conventional scintigraphy, and other imaging techniques. J Nucl Med. 2010;51:1937–49.
van der Bruggen W, Bleeker-Rovers CP, Boerman OC, Gotthardt M, Oyen WJ. PET and SPECT in osteomyelitis and prosthetic bone and joint infections: a systematic review. Semin Nucl Med. 2010;40:3–15.
Gemmel F, Van den WH, Love C, Welling MM, Gemmel P, Palestro CJ. Prosthetic joint infections: radionuclide state-of-the-art imaging. Eur J Nucl Med Mol Imaging. 2012;39:892–909.
Palestro CJ, Love C, Bhargava KK. Labeled leukocyte imaging: current status and future directions. Q J Nucl Med Mol Imaging. 2009;53:105–23.
Tondeur MC, Sand A, Ham HH. Interobserver reproducibility in the interpretation of 99mTc-labelled white blood cell scintigraphic images. Nucl Med Commun. 2008;29:1093–9.
De Vries EF, Roca M, Jamar F, Israel O, Signore A. Guidelines for the labelling of leucocytes with (99m)Tc-HMPAO. Inflammation/Infection Taskgroup of the European Association of Nuclear Medicine. Eur J Nucl Med Mol Imaging. 2010;37:842–8.
Roca M, De Vries EF, Jamar F, Israel O, Signore A. Guidelines for the labelling of leucocytes with (111)In-oxine. Inflammation/Infection Taskgroup of the European Association of Nuclear Medicine. Eur J Nucl Med Mol Imaging. 2010;37:835–41.
Banoo S, Bell D, Bossuyt P, Herring A, Mabey D, Poole F, et al. Evaluation of diagnostic tests for infectious diseases: general principles. Nat Rev Microbiol. 2010;8:S17–29.
Duet M, Pouchot J, Liote F, Faraggi M. Role for positron emission tomography in skeletal diseases. Joint Bone Spine. 2007;74:14–23.
Filippi L, Schillaci O. Usefulness of hybrid SPECT/CT in 99mTc-HMPAO-labeled leukocyte scintigraphy for bone and joint infections. J Nucl Med. 2006;47:1908–13.
Larikka MJ, Ahonen AK, Junila JA, Niemela O, Hamalainen MM, Syrjala HP. Extended combined 99mTc-white blood cell and bone imaging improves the diagnostic accuracy in the detection of hip replacement infections. Eur J Nucl Med. 2001;28:288–93.
Prandini N, Lazzeri E, Rossi B, Erba P, Parisella MG, Signore A. Nuclear medicine imaging of bone infections. Nucl Med Commun. 2006;27:633–44.
Peters AM. The utility of [99mTc]HMPAO-leukocytes for imaging infection. Semin Nucl Med. 1994;24:110–27.
Signore A, Glaudemans AW. The molecular imaging approach to image infections and inflammation by nuclear medicine techniques. Ann Nucl Med. 2011;25:681–700.
Palestro CJ, Love C, Tronco GG, Tomas MB, Rini JN. Combined labeled leukocyte and technetium 99m sulfur colloid bone marrow imaging for diagnosing musculoskeletal infection. Radiographics. 2006;26:859–70.
Palestro CJ, Love C, Miller TT. Infection and musculoskeletal conditions: Imaging of musculoskeletal infections. Best Pract Res Clin Rheumatol. 2006;20:1197–218.
Pelosi E, Baiocco C, Pennone M, Migliaretti G, Varetto T, Maiello A, et al. 99mTc-HMPAO-leukocyte scintigraphy in patients with symptomatic total hip or knee arthroplasty: improved diagnostic accuracy by means of semiquantitative evaluation. J Nucl Med. 2004;45:438–44.
Capriotti G, Chianelli M, Signore A. Nuclear medicine imaging of diabetic foot infection: results of meta-analysis. Nucl Med Commun. 2006;27:757–64.
Familiari D, Glaudemans AW, Vitale V, Prosperi D, Bagni O, Lenza A, et al. Can sequential 18F-FDG PET/CT replace WBC imaging in the diabetic foot? J Nucl Med. 2011;52:1012–9.
Nawaz A, Torigian DA, Siegelman ES, Basu S, Chryssikos T, Alavi A. Diagnostic performance of FDG-PET, MRI, and plain film radiography (PFR) for the diagnosis of osteomyelitis in the diabetic foot. Mol Imaging Biol. 2010;12:335–42.
Conflicts of interest
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Glaudemans, A.W.J.M., de Vries, E.F.J., Vermeulen, L.E.M. et al. A large retrospective single-centre study to define the best image acquisition protocols and interpretation criteria for white blood cell scintigraphy with 99mTc-HMPAO-labelled leucocytes in musculoskeletal infections. Eur J Nucl Med Mol Imaging 40, 1760–1769 (2013). https://doi.org/10.1007/s00259-013-2481-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00259-013-2481-0