Skip to main content

Advertisement

Log in

A large retrospective single-centre study to define the best image acquisition protocols and interpretation criteria for white blood cell scintigraphy with 99mTc-HMPAO-labelled leucocytes in musculoskeletal infections

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

Purpose

The diagnosis of infection is often based on clinical, pathological and microbiological results. However, these investigations lack specificity. White blood cell (WBC) scintigraphy is considered the gold standard nuclear imaging technique for diagnosing infections in bone and soft tissues (except spondylodiscitis). However, image acquisition and interpretation criteria differ amongst centres throughout the world, leading to differences in reported results. The aim of this study was to identify the most accurate WBC scintigraphy acquisition and interpretation protocols for diagnosis of bone and soft tissue infections.

Methods

Included in this retrospective study were 297 patients with suspected bone or soft tissue infection who underwent WBC scintigraphy with 99mTc-HMPAO-labelled leucocytes between 2009 and 2012. Sensitivity, specificity, accuracy, and positive and negative predictive values of WBC scintigraphy were determined for two different dual time point acquisition protocols (fixed-time acquisition and time decay-corrected acquisition) and five image interpretation methods (visual and semiquantitative with four different reference regions of interest). Final diagnosis was based on pathological and microbiological reports, and when these were not available, on clinical follow-up of at least 6 months.

Results

The best acquisition protocol was 4 h and 20 – 24 h dual time-point acquisition with time decay-corrected acquisition. When using this acquisition protocol, visual qualitative interpretation led to a sensitivity of 85.1 %, a specificity of 97.1 %, a diagnostic accuracy of 94.5 %, a positive predictive value of 88.8 % and a negative predictive value of 95.9 %. For semiquantitative analysis, the best results were found when lesion-to-reference ratios were calculated with the contralateral side as the reference tissue, except for osteomyelitis and infected osteosynthesis, for which the contralateral bone marrow was found to be the best reference tissue. Results of the semiquantitative analyses per se were not better than for visual analysis. In the optimal analysis protocol, scans are first visually evaluated, and if this gives equivocal results, semiquantitative analysis is performed. This strategy resulted in an improved sensitivity of 97.9 %, a specificity of 91.8 % and a diagnostic accuracy of 93.1 %.

Conclusion

WBC scintigraphy for bone and soft-tissue infection is best performed using a dual acquisition protocol at 4 h and at 20–24 h after injection, in which the acquisition time of the scans is corrected for decay. In most patients, visual analysis is sufficient and leads to high diagnostic accuracy. When interpretation by visual analysis is inconclusive, semiquantitative analysis adds accuracy. Based on our results, we propose a flow chart for analysing WBC scintigraphy in musculoskeletal infections.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Glaudemans AW, Signore A. FDG-PET/CT in infections: the imaging method of choice? Eur J Nucl Med Mol Imaging. 2010;37:1986–91.

    Article  PubMed  Google Scholar 

  2. Glaudemans AW, Galli F, Pacilio M, Signore A. Leukocyte and bacteria imaging in prosthetic joint infection. Eur Cell Mater. 2013;25:61–77.

    PubMed  Google Scholar 

  3. Gotthardt M, Bleeker-Rovers CP, Boerman OC, Oyen WJ. Imaging of inflammation by PET, conventional scintigraphy, and other imaging techniques. J Nucl Med. 2010;51:1937–49.

    PubMed  Google Scholar 

  4. van der Bruggen W, Bleeker-Rovers CP, Boerman OC, Gotthardt M, Oyen WJ. PET and SPECT in osteomyelitis and prosthetic bone and joint infections: a systematic review. Semin Nucl Med. 2010;40:3–15.

    Article  PubMed  Google Scholar 

  5. Gemmel F, Van den WH, Love C, Welling MM, Gemmel P, Palestro CJ. Prosthetic joint infections: radionuclide state-of-the-art imaging. Eur J Nucl Med Mol Imaging. 2012;39:892–909.

    Article  PubMed  CAS  Google Scholar 

  6. Palestro CJ, Love C, Bhargava KK. Labeled leukocyte imaging: current status and future directions. Q J Nucl Med Mol Imaging. 2009;53:105–23.

    PubMed  CAS  Google Scholar 

  7. Tondeur MC, Sand A, Ham HH. Interobserver reproducibility in the interpretation of 99mTc-labelled white blood cell scintigraphic images. Nucl Med Commun. 2008;29:1093–9.

    Article  PubMed  Google Scholar 

  8. De Vries EF, Roca M, Jamar F, Israel O, Signore A. Guidelines for the labelling of leucocytes with (99m)Tc-HMPAO. Inflammation/Infection Taskgroup of the European Association of Nuclear Medicine. Eur J Nucl Med Mol Imaging. 2010;37:842–8.

    Article  PubMed  Google Scholar 

  9. Roca M, De Vries EF, Jamar F, Israel O, Signore A. Guidelines for the labelling of leucocytes with (111)In-oxine. Inflammation/Infection Taskgroup of the European Association of Nuclear Medicine. Eur J Nucl Med Mol Imaging. 2010;37:835–41.

    Article  PubMed  Google Scholar 

  10. Banoo S, Bell D, Bossuyt P, Herring A, Mabey D, Poole F, et al. Evaluation of diagnostic tests for infectious diseases: general principles. Nat Rev Microbiol. 2010;8:S17–29.

    PubMed  Google Scholar 

  11. Duet M, Pouchot J, Liote F, Faraggi M. Role for positron emission tomography in skeletal diseases. Joint Bone Spine. 2007;74:14–23.

    Article  PubMed  Google Scholar 

  12. Filippi L, Schillaci O. Usefulness of hybrid SPECT/CT in 99mTc-HMPAO-labeled leukocyte scintigraphy for bone and joint infections. J Nucl Med. 2006;47:1908–13.

    PubMed  CAS  Google Scholar 

  13. Larikka MJ, Ahonen AK, Junila JA, Niemela O, Hamalainen MM, Syrjala HP. Extended combined 99mTc-white blood cell and bone imaging improves the diagnostic accuracy in the detection of hip replacement infections. Eur J Nucl Med. 2001;28:288–93.

    Article  PubMed  CAS  Google Scholar 

  14. Prandini N, Lazzeri E, Rossi B, Erba P, Parisella MG, Signore A. Nuclear medicine imaging of bone infections. Nucl Med Commun. 2006;27:633–44.

    Article  PubMed  Google Scholar 

  15. Peters AM. The utility of [99mTc]HMPAO-leukocytes for imaging infection. Semin Nucl Med. 1994;24:110–27.

    Article  PubMed  CAS  Google Scholar 

  16. Signore A, Glaudemans AW. The molecular imaging approach to image infections and inflammation by nuclear medicine techniques. Ann Nucl Med. 2011;25:681–700.

    Article  PubMed  Google Scholar 

  17. Palestro CJ, Love C, Tronco GG, Tomas MB, Rini JN. Combined labeled leukocyte and technetium 99m sulfur colloid bone marrow imaging for diagnosing musculoskeletal infection. Radiographics. 2006;26:859–70.

    Article  PubMed  Google Scholar 

  18. Palestro CJ, Love C, Miller TT. Infection and musculoskeletal conditions: Imaging of musculoskeletal infections. Best Pract Res Clin Rheumatol. 2006;20:1197–218.

    Article  PubMed  Google Scholar 

  19. Pelosi E, Baiocco C, Pennone M, Migliaretti G, Varetto T, Maiello A, et al. 99mTc-HMPAO-leukocyte scintigraphy in patients with symptomatic total hip or knee arthroplasty: improved diagnostic accuracy by means of semiquantitative evaluation. J Nucl Med. 2004;45:438–44.

    PubMed  Google Scholar 

  20. Capriotti G, Chianelli M, Signore A. Nuclear medicine imaging of diabetic foot infection: results of meta-analysis. Nucl Med Commun. 2006;27:757–64.

    Article  PubMed  Google Scholar 

  21. Familiari D, Glaudemans AW, Vitale V, Prosperi D, Bagni O, Lenza A, et al. Can sequential 18F-FDG PET/CT replace WBC imaging in the diabetic foot? J Nucl Med. 2011;52:1012–9.

    Article  PubMed  Google Scholar 

  22. Nawaz A, Torigian DA, Siegelman ES, Basu S, Chryssikos T, Alavi A. Diagnostic performance of FDG-PET, MRI, and plain film radiography (PFR) for the diagnosis of osteomyelitis in the diabetic foot. Mol Imaging Biol. 2010;12:335–42.

    Article  PubMed  Google Scholar 

Download references

Conflicts of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andor W. J. M. Glaudemans.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Glaudemans, A.W.J.M., de Vries, E.F.J., Vermeulen, L.E.M. et al. A large retrospective single-centre study to define the best image acquisition protocols and interpretation criteria for white blood cell scintigraphy with 99mTc-HMPAO-labelled leucocytes in musculoskeletal infections. Eur J Nucl Med Mol Imaging 40, 1760–1769 (2013). https://doi.org/10.1007/s00259-013-2481-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-013-2481-0