Development of a cost-effective modular SPECT/CT scanner

  • Original article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

Purpose

To develop a combined SPECT/CT based on a conventional gamma camera with the following design goals: (i) the subject is scanned on the same bed without moving between SPECT and CT scans, (ii) maintenance of full diagnostic utility of both scanners, (iii) a minimal equipment footprint which is adaptable to different site configurations, (iv) a modular design so that either scanner can be upgraded without impacting the other scanner and (v) cost-effectiveness.

Methods

A Philips SKYLight gamma camera was combined with a single-slice helical CT. The CT bed has been modified by mounting on wheels and is attached to a track in the floor when required. The CT bed is used for both the CT and the SPECT scans. The CT bed is parked outside the SKYLight’s active area when not required. The CT data are used for anatomical localisation, attenuation correction and definition of anatomical boundaries (e.g. lobar boundaries in the lungs).

Results

The combined SPECT/CT system is installed in a 6.2 m×4.6 m room. The CT can scan up to 1.3 m of the subject, which is usually sufficient for registration with the SPECT scan. More than 200 subjects have had SPECT/CT scans in the first year of operation. Initially, the main outcome has been improved confidence of localisation of abnormalities. Attenuation correction for all relevant radionuclides has been implemented.

Conclusion

We have developed a combined SPECT/CT using a novel approach based on a low-cost CT scanner. The design is compact, is readily upgradeable and does not compromise either machine’s diagnostic or functional capabilities.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Kuhl DE, Hale J, Eaton WL. Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy. Radiology 1966;87:278.

    PubMed  CAS  Google Scholar 

  2. Anger HO, McRae J. Transmission scintiphotography. J Nucl Med 1968;9(6):267–9.

    PubMed  CAS  Google Scholar 

  3. Sorenson JA, Briggs RC, Cameron JR. 99mTc point source for transmission scanning. J Nucl Med 1969;10(5):252–3.

    PubMed  CAS  Google Scholar 

  4. Phelps ME, Hoffman EJ, Mullani NA, Ter-Pogossian MM. Application of annihilation coincidence detection to transaxial reconstruction tomography. J Nucl Med 1975;16(3):210–24.

    PubMed  CAS  Google Scholar 

  5. Morozumi T, Nakajima M, Ogawa K, Yuta S. Attenuation correction methods using the information of attenuation distribution for single photon emission CT. Med Imag Tech 1984;2:20–8.

    Google Scholar 

  6. Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28(5):844–51.

    PubMed  CAS  Google Scholar 

  7. Butler SP, Bailey DL, McLaughlin AF, Khafagi FA, Stephens FO. SPECT evaluation of arterial perfusion in regional chemotherapy. J Nucl Med 1988;29(5):593–8.

    PubMed  CAS  Google Scholar 

  8. Beyer T, Kinahan PE, Townsend DW, Sashin D. The use of X-ray CT for attenuation correction of PET data. In: Trendler RC (ed) IEEE Nuclear Science Symposium and Medical Imaging Conference; 1994; Norfolk, VA, USA: Inst of Electrical and Electronic Engineers; 1994. p. 1573–7.

  9. Beyer T, Townsend DW, Brun T, Kinahan PE, Charron M, Roddy R, et al. A combined PET/CT scanner for clinical oncology. J Nucl Med 2000;41(8):1369–79.

    PubMed  CAS  Google Scholar 

  10. Lang TF, Hasegawa BH, Liew SC, Brown JK, Blankespoor SC, Reilly SM, et al. Description of a prototype emission-transmission computed tomography imaging system. J Nucl Med 1992;33(10):1881–7.

    PubMed  CAS  Google Scholar 

  11. Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, et al. Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med 2000;27(6):619–27.

    Article  PubMed  CAS  Google Scholar 

  12. Tan P, Bailey DL, Meikle SR, Eberl S, Fulton RR, Hutton BF. A scanning line source for simultaneous emission and transmission measurements in SPECT. J Nucl Med 1993;34(10):1752–60.

    PubMed  CAS  Google Scholar 

  13. Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imag 1994;MI-13(4):601–9.

    Article  Google Scholar 

  14. Brown S, Bailey DL, Baldock CA. Relationship between CT Hounsfield units and linear attenuation coefficients for a number of single photon-emitting radionuclides [abstract]. J Nucl Med 2006;47(5 Suppl):381P.

    Google Scholar 

  15. Philips. Installation and Siting Support - CT/PQ SERIES SYSTEM (400 VAC); 2000.

  16. Moss M, McLean D. Paediatric and adult computed tomography practice and patient dose in Australia. Australasian Radiol 2006;50:33–40.

    Article  CAS  Google Scholar 

  17. Kneifel S. Radiation dose and radiation protection. In: von Shultness GK (ed) Clinical molecular anatomic imaging. Philadelphia: Lippincott; 2003. p. 68–71.

    Google Scholar 

  18. ICRP. ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals; 1988.

  19. ImPACT. ImPACT CT dose calculator (http://www.impactscan.org/ctdosimetry.htm). London: NHS(UK); 2006. Accessed 31/10/2006.

  20. Towson JEC. Radiation dosimetry and protection in PET. In: Valk P, Bailey DL, Townsend DW, Maisey MN (eds) Positron emission tomography: basic science and clinical practice. London: Springer, 2003.

    Google Scholar 

  21. Roach PJ, Schembri GP, Ho Shon IA, Bailey EA, Bailey DL. SPECT/CT imaging using a spiral CT scanner for anatomical localisation: impact on diagnostic accuracy and reporter confidence in clinical practice. Nucl Med Commun 2006;27:977–87.

    Article  PubMed  Google Scholar 

  22. Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, et al. Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med 2006;47(7):1227–34.

    PubMed  Google Scholar 

  23. Bailey DL. Is PET the future of nuclear medicine? (Invited Commentary). Eur J Nucl Med Mol Imag 2003;30(7):1045–6.

    Article  Google Scholar 

  24. Kashiwagi T, Yutani K, Fukuchi M, Naruse H, Iwasaki T, Yokozuka K, et al. Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT. Ann Nucl Med 2002;16(4):255–61.

    Article  PubMed  Google Scholar 

  25. Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Squire OD, Braban LE, et al. Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. Med Phys 2002;29(3):366–71.

    Article  PubMed  CAS  Google Scholar 

  26. Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 2003;348:2500–7.

    Article  PubMed  Google Scholar 

  27. Bar-Shalom R, Yefremov N, Guralnik L, Gaitini D, Frenkel A, Kuten A, et al. Clinical performance of PET/CT in evaluation of cancer: additional value for diagnostic imaging and patient management. J Nucl Med 2003;44(8):1200–9.

    PubMed  Google Scholar 

  28. Coleman R, Delbeke D, Guiberteau M, Conti P, Royal H, Weinreb J, et al. Concurrent PET/CT with an integrated imaging system: intersociety dialogue from the Joint Working Group of the American College of Radiology, the Society of Nuclear Medicine, and the Society of Computed Body Tomography and Magnetic Resonance. J Nucl Med 2005;46:1225–39.

    PubMed  Google Scholar 

  29. Townsend DW, Cherry SR. Combining anatomy and function: the path to true image fusion. Eur Radiol 2001;11(10):1968–74.

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgements

Financial and resource support for this project came from a variety of sources, including Philips Medical Systems (ADAC Labs, Milpitas, CA, USA), the Northern Sydney Health Research Committee Research Infrastructure Block Grants scheme, the Royal North Shore Staff Specialists’ Private Practice Trust Fund, the Woolcock Institute for Medical Research, the Institute of Medical Physics of the University of Sydney, Insight Oceania and Nuclear Fields (Aust) Pty Ltd. We greatly appreciated the efforts of Peter Matthews and Dan Le of Philips Medical Systems (Aust) for the non-standard CT installation and the staff of Philips Medical Systems (ADAC Labs, Milpitas, CA, USA) and Nino Pennino of Insight Oceania, who supported the integration of the SKYLight gamma camera.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dale L. Bailey.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bailey, D.L., Roach, P.J., Bailey, E.A. et al. Development of a cost-effective modular SPECT/CT scanner. Eur J Nucl Med Mol Imaging 34, 1415–1426 (2007). https://doi.org/10.1007/s00259-006-0364-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-006-0364-3

Keywords

Navigation