Abstract
Purpose
The aim of this study was to investigate the intra-individual reproducibility of left ventricular volume and ejection fraction measurements in living rat using pinhole gated single-photon emission computed tomography (SPECT).
Methods
Eight normal male Wistar rats underwent four pinhole gated SPECT acquisitions over a 1-month period. Two pinhole gated myocardial perfusion SPECT studies were acquired at a 1-week interval after injecting the animals with 439±52 MBq of 99mTc-sestamibi. Subsequently, 1 week after the perfusion studies, two pinhole gated blood pool SPECT studies were acquired at a 1-week interval after in vivo labelling of the red blood cells using 520±49 MBq of 99mTc-pertechnetate. Pinhole gated SPECT acquisitions were done on a single-head gamma camera equipped with a pinhole collimator with a 3-mm opening and 165-mm focal length. Parameters of acquisition were as follows: 44 mm radius of rotation, 360° rotation using a circular orbit, 64 projections, 64×64 matrix, gating using 16 time frames and 22-min acquisition time. The projection data were reconstructed with a modified version of OSEM taking into account the pinhole geometry and incorporating a prior assumption about the temporal properties of gated SPECT studies to reduce noise. Left ventricular volumes and ejection fraction were measured using automatic quantification algorithms. Inter-study, inter-observer and intra-observer reproducibility was investigated.
Results
Pinhole gated myocardial perfusion and pinhole gated blood pool images were of high quality in all animals. No significant differences were observed between the repeated measurements. The pinhole gated myocardial perfusion SPECT studies indicated that differences between repeated measurements larger than 41 μl for end-diastolic volume, 17 μl for end-systolic volume and 3% for ejection fraction were significant. The pinhole gated blood pool SPECT studies indicated that differences between repeated measurements larger than 42 μl for end-diastolic volume, 38 μl for end-systolic volume and 5% for ejection fraction were significant. In addition to the reproducibility measures, the accuracy of volume measurements in pinhole gated blood pool SPECT was confirmed by a phantom study. Excellent correlations were observed between the measured volumes and the actual phantom volumes.
Conclusion
Pinhole gated SPECT is an accurate and reproducible technique for cardiac studies of small animals. Because this technique is non-invasive, the same animal can be imaged repetitively, allowing follow-up studies.
Similar content being viewed by others
References
Wu MC, Gao DW, Sievers RE, Lee RJ, Hasegawa BH, Dae MW. Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice. J Am Coll Cardiol 2003;42:576–82.
Beekman FJ, McElroy DP, Berger F, Gambhir SS, Hoffman EJ, Cherry SR. Towards in vivo nuclear microscopy: iodine-125 imaging in mice using micro-pinholes. Eur J Nucl Med Mol Imaging 2002;29:933–8.
Del Guerra A, Belcari N. Advances in animal PET scanners. Q J Nucl Med 2002;46:35–47.
Habraken JB, de Bruin K, Shehata M, Booij J, Bennink R, van Eck Smit BL, Busemann Sokole E. Evaluation of high-resolution pinhole SPET using a small rotating animal. J Nucl Med 2001;42:1863–9.
Weber DA, Ivanovic M. Ultra-high-resolution imaging of small animals: implications for preclinical and research studies. J Nucl Cardiol 1999;6:332–4.
Ishizu K, Mukai T, Yonekura Y, Pagani M, Fujita T, Magata Y, et al. Ultra-high resolution SPET system using four pinhole collimators for small animal studies. J Nucl Med 1995;36:2282–7.
Vanhove C, Defrise M, Franken PR, Everaert H, Deconinck F, Bossuyt A. Interest of the ordered subsets expectation maximization (OS–EM) algorithm in pinhole SPET reconstruction: a phantom study. Eur J Nucl Med 2000;27:140–6.
Vanhove C, Franken PR, Defrise M, Deconinck F, Bossuyt A. Reconstruction of gated myocardial perfusion SPET incorporating temporal information during iterative reconstruction. Eur J Nucl Med Mol Imaging 2002;29:465–72.
Li J, Jaszczak RJ, Greer KL, Coleman RE. A filtered backprojection algorithm for pinhole SPET with a displaced centre of rotation. Phys Med Biol 1994;39:165–76.
Goris ML, Thompson C, Malone LJ, Franken PR. Modelling the integration of myocardial regional perfusion and function. Nucl Med Commun 1994;15:9–20.
Everaert H, Franken PR, Flamen P, Goris M, Momen A, Bossuyt A. Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on radial distribution of count rate density across the myocardial wall. Eur J Nucl Med 1996;23:1628–33.
Vanhove C, Franken PR, Defrise M, Momen A, Everaert H, Bossuyt A. Automatic determination of left ventricular ejection fraction from gated blood pool tomography. J Nucl Med 2001;42:401–7.
Vanhove C, Franken PR. Left ventricular ejection fraction and volumes from gated blood pool tomography: comparison between two automatic algorithms working in three-dimensional space. J Nucl Cardiol 2001;8:466–71.
Vanhove C, Walgraeve N, De Geeter F, Franken PR. Gated myocardial perfusion tomography versus gated blood pool tomography to calculate left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 2002;29:735–41.
Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPET: comparison of 4 software programs. J Nucl Med 2001;42:1571–8.
Nakajima K, Taki J, Higuchi T, Kawano M, Taniguchi M, Maruhashi K, et al. Gated SPET quantification of small heart: mathematical simulation and clinical application. Eur J Nucl Med 2000;27:1372–9.
Wise RG, Huang CLH, Gresham GA, Al-Shafei AIM, Carpenter TA, Hall LD. Magnetic resonance imaging analysis of left ventricular function in normal and spontaneously hypertensive rats. J Physiol 1998;3:873–87.
Wise RG, Huang CLH, Al-Shafei AIM, Carpenter TA, Hall LD. Geometric models of left ventricular contraction from MRI of the normal and spontaneously hypertensive rat heart. Phys Med Biol 1999;44:2657–76.
Nahrendorf M, Wiesmann F, Hiller KH, Hu K, Waller C, Ruff J, et al. Serial cine-magnetic resonance imaging of left ventricular remodelling after myocardial infarction in rats. J Magn Reson Imaging 2001;14:547–55.
Croteau E, Benard F, Cadorette J, Gauthier ME, Aliagra A, Bentourkia M, Lecomte R. Quantitative gated PET for the assessment of left ventricular function in small animals. J Nucl Med 2003;44:1655–61.
Atkins HL, Thomas SR, Buddemeyer U, Chevru LR. MIRD dose estimate report No. 14: radiation absorbed dose from technetium-99m-labeled red blood cells. J Nucl Med 1990;31:378–80.
Fajardo LF, editor. Pathology of radiation injury. New York: Masson; 1983. Chap. 3.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Vanhove, C., Lahoutte, T., Defrise, M. et al. Reproducibility of left ventricular volume and ejection fraction measurements in rat using pinhole gated SPECT. Eur J Nucl Med Mol Imaging 32, 211–220 (2005). https://doi.org/10.1007/s00259-004-1649-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00259-004-1649-z