Skip to main content
Log in

Technetium-99m methoxyisobutylisonitrile imaging for parathyroid adenoma: relationship to P-glycoprotein or multidrug resistance-related protein expression

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract.

Gland size has been reported to have a major influence on localisation of parathyroid adenomas by technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) imaging. It has also been suggested that P-glycoprotein (Pgp) expression in parathyroid adenomas may influence localisation because false negative studies have been reported with large tumours and true positives with very small tumours. Therefore, the purpose of this study was to retrospectively evaluate the relationship between 99mTc-MIBI parathyroid imaging results and Pgp or multidrug resistance-related protein (MRP) expression in parathyroid adenomas. Before surgery, 47 patients with large parathyroid adenomas (larger than 1.5 g) underwent early and delayed parathyroid imaging, 10 min and 2 h after intravenous injection of 99mTc-MIBI. Immunohistochemical analyses (IHA) were performed, using multiple non-consecutive sections of the operative specimens, to detect Pgp or MRP expression. According to the results of IHA, the 34 parathyroid adenomas were separated into four groups: (1) three adenomas positive for both Pgp and MRP expression, (2) one adenoma positive for Pgp but negative for MRP expression, (3) four adenomas negative for Pgp but positive for MRP expression and (4) 39 adenomas with negative for both Pgp and MRP expression. All 39 adenomas in group 4 could be detected by 99mTc-MIBI parathyroid imaging. None of the eight adenomas in groups 1–3 could be detected by 99mTc-MIBI parathyroid imaging (P<0.05). It is concluded that not only the size of parathyroid adenomas but also significant Pgp or MRP expression limits the sensitivity of 99mTc-MIBI imaging in localising parathyroid adenomas preoperatively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 30 December 2001 and in revised form 24 February 2002

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kao, A., Shiau, YC., Tsai, SC. et al. Technetium-99m methoxyisobutylisonitrile imaging for parathyroid adenoma: relationship to P-glycoprotein or multidrug resistance-related protein expression. Eur J Nucl Med 29, 1012–1015 (2002). https://doi.org/10.1007/s00259-002-0817-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-002-0817-2

Navigation