Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

The purpose of this study was to evaluate the accuracy of myocardial imaging by means of high-resolution single-photon emission tomography (SPET) with a pinhole collimator in rats with experimental infarction. Myocardial infarctions were induced in male Wistar rats by ligation of the left coronary artery for 30 min, followed by reperfusion. Two days after the reperfusion, pinhole SPET was performed after the intravenous administration of 111 MBq of thallium-201 chloride, using a rotating gamma camera equipped with a pinhole insert (2.0-mm aperture) in a low-energy pinhole collimator. SPET projection data were collected at 6° increments over 360° using a 4-cm radius of rotation to reconstruct the short- and long-axis images. Projection data were acquired in 15 or 30 s, the SPET imaging being accomplished within 40 min after the injection of201T1. After SPET, the rats were sacrificed to remove the hearts for autoradiography (ARG) and nitroblue tetrazolium (NBT) staining as a visual correlative study. Quantitative correlative studies between pinhole SPET and ARG were performed with linear regression analysis for infarct size and distribution properties (relative counts on SPET images and relative density on autoradiographs) on the short-axis sections. All infarcts (4 mm in minimum diameter) in seven rats were detected by pinhole SPET. The SPET images in rats with or without myocardial infarction were consistent with the findings of ARG and NBT staining. There were significant correlations between pinhole SPET and ARG with respect to the infarct size (r=0.933,P <0.001;n=15) and the relative radiotracer distribution (r=0.931,P <0.001; n=68). This study therefore confirmed the accuracy of myocardial pinhole SPET imaging in rats with myocardial infarction. This method may partially substitute for ARG and prove useful for assessing new myocardial imaging agents in vivo in small laboratory animals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Selye H, Bajusz E, Grasso S, Mendell P. Simple techniques for the surgical occlusion of coronary vessels in the rat.Angiology 1960; 11: 398–403.

    PubMed  Google Scholar 

  2. Deloche A, Fabiani JN, Camilleri JP, Relland J, Joseph D, Carpentier A, Dubost C. The effect of coronary artery reperfusion on the extent of myocardial infarction.Am Heart J 1977; 93: 358–366.

    PubMed  Google Scholar 

  3. Jaszczak RJ, Li J, Wang H, Zalutsky MR, Coleman RE. Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT.Phys Med Biol 1994; 39: 425–437.

    PubMed  Google Scholar 

  4. Palmer J, Wollmer P. Pinhole emission computed tomography: method and experimental evaluation.Phys Med Biol 1990; 35: 339–350.

    PubMed  Google Scholar 

  5. Marriott CJ, Cadorette JE, Lecomte R, Scasnar V, Rousseau J, van Lier JE. High-resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using avalanche photodiode detectors.J Nucl Med 1994; 35: 1390–1397.

    PubMed  Google Scholar 

  6. Inoue T, Endo K, Hirano T. Imaging of bone metabolism with fluorine-l8-fluoride ion using a high resolution animal PET.Bioimages 1993; 1: 27–30.

    Google Scholar 

  7. Weber DA, Ivanovic M, Franceschi D, Strand S-E, Erlandsson K, Franceschi M, Atkins HL, Coderre JA, Susskind H, Button T, Ljunggren K. Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.J Nucl Med 1994: 35: 342–348.

    PubMed  Google Scholar 

  8. Ishizu K, Mukai T, Yonekura Y, Pagani M, Fujita T, Magata Y, Nishizawa S, Tamaki N, Shibasaki H, Konishi J. Ultra-high resolution SPECT system using four pinhole collimators for small animal studies.J Nucl Med 1995; 36: 2282–2287.

    PubMed  Google Scholar 

  9. Feldkamp LA, Davies LC, Kress JW. Practical cone beam algorithm.J Opt Soc Am [A] 1984; 1: 612–619.

    Google Scholar 

  10. Nachlas MM, Shnitka TK. Macroscopic identification of early myocardial infarcts by alterations in dehydrogenase activity.Am J Pathol 1963; 42: 379–405.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yukihiro, M., Inoue, T., Iwasaki, T. et al. Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator. Eur J Nucl Med 23, 896–900 (1996). https://doi.org/10.1007/BF01084362

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01084362

Key words

Navigation