Abstract
Single photon emission computed tomography (SPECT) of the lung was performed, in addition to conventional camera scintigraphy, in 41 patients with pulmonary disorders as well as with regular pulmonary perfusion. For SPECT investigation a rotating gamma camera (Gammatome) was used consisting of a system with a high-resolution parallel-hole collimator interfaced with a digital computer. In 6 of 41 patients the diagnostic accuracy of pulmonary scintigraphy was improved by SPECT. Topographic identification of segmental perfusion defects in pulmonary embolism seems to be particularly promising. Special abnormalities that cannot be assessed by conventional lung imaging are mediastinal hernia and recessus retrotrachealis as a normal variant. For a detailed evaluation of this method a larger number of patients must be investigated.
Similar content being viewed by others
References
Alderson PO, Doppmann JL, Diamond SS (1978) Ventilation-perfusion lung imaging and selective pulmonary angiography in dogs with experimental pulmonary embolism. JNM 19:164–171
Biersack HJ, Felix R, Breuel HP (1977) Inhalations- und Perfusionsszintigraphie bei Lungenerkrankungen. Therapiewoche 27:3958–3972
Budinger TF, Gullberg GT, Huesman RH (1979) Emission computed tomography. In: Herman GT (ed) Image Reconstruction from Projections. Springer, Berlin Heidelberg New York, 147–246
Caride VJ, Puri S, Slavin JD (1976) The usefulness of posterior oblique views in perfusion lung imaging. Radiology 121:669–671
Lopez-Majano V, Tow DE, Wagner HN Jr (1966) Regional distribution of pulmonary arterial blood flow in emphysema. JAMA 197:81
Mack JF, Wellman HN, Saenger EL (1969) Oblique pulmonary scintiphotography in the analysis of perfusion abnormalities due to embolism. JNM 10:420 (abstr)
Neumann RD, Sostmann HD, Gottschalk A (1980) Current status of ventilation-perfusion imaging. Sem Nucl Med 10:198–217
Nielson PE, Kirchner PT, Gerber FH (1977) Oblique views in lung perfusion scanning: Clinical utility and limitations. JNM 18:967–972
Quinn JL (1971) Perfusion scanning in chronic obstructive lung disease. Semin Nucl Med 1:185–194
Roucayrol JC, Fonroget J, Brunol J (1980) Valeur diagnostique et limitations statistiques de la TATE. In: Schmidt HAE, Riccabona G (eds) Nuklearmedizin — die klinische Relevanz der Nuklearmedizin. Schattauer, Stuttgart, pp 114–117
Secker-Walker RH (1976) Lung scanning. In: Gottschalk A, Potchen EJ (eds) Diagnostic Nuclear Medicine. Williams & Wilkins, Baltimore, pp 341–398
Winkler C (1974) Lungenszintigraphie in der Diagnostik des Bronchialkarzinoms. Röntgen-Bl 27:173–180
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Biersack, H.J., Altland, H., Knopp, R. et al. Single photon emission computed tomography of the lung: Preliminary results. Eur J Nucl Med 7, 166–170 (1982). https://doi.org/10.1007/BF00443925
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00443925