Skip to main content
Log in

Single photon emission computed tomography of the lung: Preliminary results

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Single photon emission computed tomography (SPECT) of the lung was performed, in addition to conventional camera scintigraphy, in 41 patients with pulmonary disorders as well as with regular pulmonary perfusion. For SPECT investigation a rotating gamma camera (Gammatome) was used consisting of a system with a high-resolution parallel-hole collimator interfaced with a digital computer. In 6 of 41 patients the diagnostic accuracy of pulmonary scintigraphy was improved by SPECT. Topographic identification of segmental perfusion defects in pulmonary embolism seems to be particularly promising. Special abnormalities that cannot be assessed by conventional lung imaging are mediastinal hernia and recessus retrotrachealis as a normal variant. For a detailed evaluation of this method a larger number of patients must be investigated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Alderson PO, Doppmann JL, Diamond SS (1978) Ventilation-perfusion lung imaging and selective pulmonary angiography in dogs with experimental pulmonary embolism. JNM 19:164–171

    Google Scholar 

  2. Biersack HJ, Felix R, Breuel HP (1977) Inhalations- und Perfusionsszintigraphie bei Lungenerkrankungen. Therapiewoche 27:3958–3972

    Google Scholar 

  3. Budinger TF, Gullberg GT, Huesman RH (1979) Emission computed tomography. In: Herman GT (ed) Image Reconstruction from Projections. Springer, Berlin Heidelberg New York, 147–246

    Google Scholar 

  4. Caride VJ, Puri S, Slavin JD (1976) The usefulness of posterior oblique views in perfusion lung imaging. Radiology 121:669–671

    Google Scholar 

  5. Lopez-Majano V, Tow DE, Wagner HN Jr (1966) Regional distribution of pulmonary arterial blood flow in emphysema. JAMA 197:81

    Google Scholar 

  6. Mack JF, Wellman HN, Saenger EL (1969) Oblique pulmonary scintiphotography in the analysis of perfusion abnormalities due to embolism. JNM 10:420 (abstr)

    Google Scholar 

  7. Neumann RD, Sostmann HD, Gottschalk A (1980) Current status of ventilation-perfusion imaging. Sem Nucl Med 10:198–217

    Google Scholar 

  8. Nielson PE, Kirchner PT, Gerber FH (1977) Oblique views in lung perfusion scanning: Clinical utility and limitations. JNM 18:967–972

    Google Scholar 

  9. Quinn JL (1971) Perfusion scanning in chronic obstructive lung disease. Semin Nucl Med 1:185–194

    Google Scholar 

  10. Roucayrol JC, Fonroget J, Brunol J (1980) Valeur diagnostique et limitations statistiques de la TATE. In: Schmidt HAE, Riccabona G (eds) Nuklearmedizin — die klinische Relevanz der Nuklearmedizin. Schattauer, Stuttgart, pp 114–117

    Google Scholar 

  11. Secker-Walker RH (1976) Lung scanning. In: Gottschalk A, Potchen EJ (eds) Diagnostic Nuclear Medicine. Williams & Wilkins, Baltimore, pp 341–398

    Google Scholar 

  12. Winkler C (1974) Lungenszintigraphie in der Diagnostik des Bronchialkarzinoms. Röntgen-Bl 27:173–180

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Biersack, H.J., Altland, H., Knopp, R. et al. Single photon emission computed tomography of the lung: Preliminary results. Eur J Nucl Med 7, 166–170 (1982). https://doi.org/10.1007/BF00443925

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00443925

Keywords

Navigation