TABLE 3

Diagnostic Accuracy of 18F-NaF PET/CT in 211 Patients with Final Diagnosis for Presence or Absence of Bone Metastases

M0 by final diagnosis (n = 147)M1 by final diagnosis (n = 64)SensitivitySpecificityPPVNPV
ScaleM0EquivocalM1M0EquivocalM1
3-category
 Observer 11367454550.86 (0.75–0.93)0.97 (0.93–0.99)0.93 (0.84–0.98)0.94 (0.89–0.97)
0.92 (0.83–0.97)0.93 (0.87–0.96)0.84 (0.74–0.92)0.97 (0.92–0.99)
 Observer 212221452570.89 (0.79–0.96)0.97 (0.93–0.99)0.93 (0.84–0.98)0.95 (0.91–0.98)
0.92 (0.83–0.97)0.83 (0.76–0.89)0.70 (0.59–0.80)0.96 (0.91–0.99)
 Consensus13211462560.88 (0.77–0.94)0.97 (0.93–0.99)0.93 (0.84–0.98)0.95 (0.90–0.98)
0.91 (0.81–0.96)0.90 (0.84–0.94)0.79 (0.68–0.88)0.96 (0.91–0.98)
Dichotomous
 Observer 114167570.89 (0.79–0.96)0.96 (0.91–0.98)0.91 (0.80–0.96)0.95 (0.91–0.98)
 Observer 2137107570.89 (0.79–0.96)0.93 (0.88–0.97)0.85 (0.74–0.93)0.95 (0.91–0.98)
 Consensus14258560.88 (0.77–0.94)0.97 (0.92–0.99)0.92 (0.82–0.97)0.94 (0.90–0.98)
  • CI = confidence interval; PPV = positive predictive value; NPV = negative predictive value.

  • Data are for 2 observers (in cases of disagreement, observers reevaluated scans and reached consensus diagnosis) and for optimistic analytic approach (pessimistic approach is in italics). Data in parentheses are 95% confidence intervals.