TABLE 1

Physical Characteristics of Common Radionuclides Used in Radiotherapy (89)

RadionuclideHalf-life (h)Maximum energyMaximum particle range in soft tissue (mm)
177L162β (498 keV), γ (208 keV)2
90Y64β (2,250 keV)11
131I193β (610 keV), γ (362 keV)2.9
225Ac240α (6 MeV)No clear range because of successive α-emissions