TABLE 1

Results from Logit TCP Models

Dose metric−2logLAUC50% TCP90% TCPSensitivitySpecificityDose metric P
Mean dose394.20.884292 Gy554 Gy0.7500.8890.014
AD30395.70.896354 Gy650 Gy0.7920.8330.012
V500 (AD)388.40.87218%51%0.7500.8890.109
EUD, α = 0.0001 Gy−1394.20.882291 Gy552 Gy0.7500.8890.014
EUD, α = 0.0002*Gy−1394.10.880290 Gy551 Gy0.7500.8890.014
EUD, α = 0.0005 Gy−1394.20.877286 Gy546 Gy0.7500.8890.014
EUD, α = 0.002 Gy−1395.50.873269 Gy520 Gy0.7500.8260.014
Mean BED409.80.869441 Gy953 Gy0.7600.8890.007
BED50399.70.896406 Gy840 Gy0.7500.8890.008
V500 (BED)389.00.86633.2%79%0.8750.8330.074
EUBED, α = 0.0001 Gy−1397.80.903463 Gy890 Gy0.7500.8890.008
EUBED, α = 0.0005*Gy−1396.20.903442 Gy856 Gy0.7500.8890.009
EUBED, α = 0.0008 Gy−1396.60.905427 Gy832 Gy0.7500.8890.009
EUBED, α = 0.002 Gy−1398.60.884380 Gy754 Gy0.7500.8260.009
  • * Maximum likelihood value of α.

  • −2logL = log likelihood.

  • All AUCs were statistically significant, with P < 0.0001; 50% and 90% TCP are value of dose metric corresponding to 50% and 90% predicted TCP, respectively. Dose metric P is P value of dose metric from logistic model. Sensitivity and specificity were calculated using 50% TCP as cutoff for predicted response. Supplemental Table 6 shows results corresponding to full range of α values tested.