TABLE 1

Activity Yield, Molar Activity, Partition Coefficient, and Binding Affinity of 18F-Labeled PSMA Radiotracers

TracerActivity yield* (%, isolated)Molar activity (GBq/μmol)LogD7.4 (n = 3)Ki (nM) (n = 3)
18F-DCFPyL12 ± 3 (n = 7)118 ± 37 (n = 7)−3.12 ± 0.222.0 ± 0.8
18F-17 ± 4 (n = 4)70 ± 19 (n = 4)−3.43 ± 0.3514.4 ± 2.7
18F-24 ± 2 (n = 3)89 ± 26 (n = 3)−4.26 ± 0.0411.8 ± 0.9
18F-35 ± 1 (n = 3)56 ± 15 (n = 3)−4.01 ± 0.1425.9 ± 5.7
18F-416 ± 2 (n = 3)148 ± 89 (n = 3)−3.34 ± 0.0227.6 ± 3.8
18F-513 ± 10 (n = 2)137 ± 22 (n = 2)−3.52 ± 0.211.14 ± 0.26
18F-615 ± 2 (n = 6)278 ± 73 (n = 6)−2.28 ± 0.011.90 ± 0.68
18F-710 ± 5 (n = 3)92 ± 22 (n = 2)−3.24 ± 0.0316.5 ± 5.5
18F-87 ± 6 (n = 3)211 ± 48 (n = 3)−3.58 ± 0.360.22 ± 0.01
  • * Activity yields are reported at end of synthesis (1 h for DCFPyL, 40 min for 1–8) (with no correction for decay).

  • Molar activities are reported at time of quality control injection, shortly after end of synthesis.