TABLE 4

Lung Dose Estimates in the 10 Patients with a LSF of 10% or More as Determined from Planar 99mTc-MAA Imaging

Lung dose (Gy)
LSF (%)90Y activity (MBq)PlanarSPECT/CT
Patient no.PlanarSPECT/CTLung volume (L)SIRT areaResinGlassLSFLSF and lung volumeLSFLSF and lung volume
511.12.93.84Right lobe1.0705.95.31.61.4
3.60019.917.75.24.6
612.03.81.80Left lobe7304.48.11.42.6
2.000*12.022.33.87.1
1018.09.32.22Whole liver1.70015.323.47.912.1
5.00045.068.823.235.5
1832.313.52.41Left lobe82013.218.45.67.7
2.730*44.161.218.525.7
1926.515.73.17Whole liver1.90025.226.314.915.6
6.92091.795.954.256.6
2111.74.42.98Whole liver1.82010.612.74.04.8
8.49049.659.518.922.6
2911.14.22.60Whole liver1.5208.510.93.24.2
4.48025.032.29.512.3
3011.34.34.52Left lobe9005.13.81.91.4
2.200*12.59.34.73.5
3310.01.24.48Left lobe7703.82.90.50.3
2.07010.37.71.20.9
3414.57.43.02Whole liver1.85013.414.96.87.6
2.25016.418.18.39.2
  • * Intended treatment with glass microspheres.

  • Estimates based on LSF from planar imaging or SPECT/CT considering either standard lung mass (1,000 g) or individual lung volume as measured by CT and tissue density of 0.3 g/mL.