TABLE 3

Linear Fit of SPECT to PET Regional MBF and Resulting Sensitivity, Specificity, and AROC for Detecting Regional PET MFR Less Than 2 with SPECT MFR for Different Correction Approaches

SPECT MBF vs. PET MBF linear fitRegional PET MFR < 2 (n = 23/87)
CorrectionRResidualRel. Diff.ThresholdSensitivitySpecificityAccuracyAROC
−BB, −AC, −MC0.6390.05 ± 0.65*−0.05 ± 0.471.640.650.810.770.800
+MC0.6680.00 ± 0.57*,−0.08 ± 0.451.810.740.780.770.831
+AC, −MC0.7420.08 ± 0.540.00 ± 0.542.240.740.720.720.770
+MC0.8160.08 ± 0.44,0.00 ± 0.442.260.780.700.720.780
+BB, −AC, −MC0.7380.01 ± 0.49*−0.04 ± 0.392.060.910.660.720.850
+MC0.780−0.04 ± 0.41*−0.07 ± 0.381.790.780.800.790.866
+AC, −MC0.7690.07 ± 0.480.01 ± 0.371.810.700.860.820.825
+MC0.8470.05 ± 0.370.01 ± 0.331.850.700.860.820.841
  • * +BB vs. –BB for R, AROC, P < 0.004.

  • +AC vs. –AC for R, AROC, P < 0.004.

  • +MC vs. –MC for R, AROC, P < 0.004.

  • Threshold chosen to maximize sensitivity × specificity, using mean Renkin–Crone model parameters (Table 1).

  • Rel. Diff. = (SPECT/PET)/mean.