TABLE 3

Reproducibility of Kinetic Rate Constants Using 20-Minute TD*

Tumor level (n = 248)Voxel level
Kinetic rate constantrSlope (95% CI)Intercept (95% CI)RMSDMean difference (95% LoA)rSlopeInterceptMean difference (95% LoA)
K3 (min−1)0.981.000 (0.977 to 1.003)3E−5 (−6E−5 to 1E−4)0.0005 ± 0.00043.5E−5 (−0.0008 to 0.0009)0.981.034−9E−61.1E−4 (−0.0015 to 0.0017)
K1 (min−1)1.000.966 (0.955 to 0.977)0.016 (0.012 to 0.020)0.017 ± 0.0100.004 (−0.024 to 0.033)0.990.9710.0170.007 (−0.042 to 0.057)
K1/k20.981.073 (1.045 to 1.100)−0.08 (−0.11 to −0.060.06 ± 0.03−0.02 (−0.09 to 0.06)0.961.064−0.08−0.02 (−0.16 to 0.12)
vB0.990.992 (0.977 to 1.007)−3E−3 (−6E−3 to 2E−8)0.01 ± 0.01−0.004 (−0.026 to 0.017)0.980.977−4E−4−0.005 (−0.045 to 0.036)
DV0.981.088 (1.060 to 1.115)−0.10 (-0.12 to −0.07)0.04 ± 0.02−0.01 (−0.08 to 0.05)0.961.073−0.09−0.02 (−0.13 to 0.09)
  • * 0- to 10-min dynamic + 10-min static acquisition starting at 160 min after injection (20-min total acquisition time).

  • CI = confidence interval; RMSD = root-mean-square deviation; LoA = limits of agreement.