TABLE 4

Reproducibility of Kinetic Rate Constants Using 15-Minute TD*

Tumor level (n = 248)Voxel level
Kinetic rate constantrSlope (95% CI)Intercept (95% CI)RMSDMean difference (95% LoA)rSlopeInterceptMean difference (95% LoA)
k3 (min−1)0.951.057 (1.010 to 1.103)7E−5 (−9E−5 to 2E−4)0.0011 ± 0.00090.0002 (−0.0014 to 0.0015)0.911.0705E−50.0003 (−0.0032 to 0.0037)
K1 (min−1)0.990.948 (0.931 to 0.965)0.033 (0.026 to 0.040)0.035 ± 0.0180.015 (−0.029 to 0.058)0.980.9620.0310.019 (−0.065 to 0.102)
K1/k20.921.089 (1.025 to 1.154)−0.11 (−0.18 to −0.050.14 ± 0.06−0.03 (−0.18 to 0.12)0.811.072−0.11−0.04 (−0.37 to 0.29)
vB0.990.981 (0.958 to 1.004)−5E−3 (−9E−3 to 3E−3)0.02 ± 0.01−0.008 (−0.039 to 0.022)0.970.970−3E−3−0.009 (−0.061 to 0.043)
DV0.931.124 (1.059 to 1.188)−0.15 (−0.21 to −0.08)0.12 ± 0.05−0.03 (−0.16 to 0.10)0.821.095−0.13−0.04 (−0.30 to 0.22)
  • * 0- to 5-min dynamic + 10-min static acquisition starting at 160 min after injection (15-min total acquisition time).

  • CI = confidence interval; RMSD = root-mean-square deviation; LoA = limits of agreement.