TABLE 1

Radiochemical Data from Preparation of N-11C-Methyl-Taurine–Conjugated Bile Acids

TracerRadiochemical conversion*Radiochemical yield (not decay-corrected)Radiochemical yield (decay-corrected)Isolated radioactivityRadiochemical purity
11C-MTCA78% ± 5%30% ± 4%71% ± 7%5.0–5.8 GBq>99%
11C-MTCDCA75% ± 4%26% ± 3%68% ± 4%4.7–6.4 GBq>99%
11C-MTDCA77% ± 2%25% ± 4%61% ± 8%2.2–6.2 GBq>99%
11C-MTUDCA77% ± 4%25% ± 3%66% ± 6%2.5–6.0 GBq>99%
11C-MTLCA77% ± 6%22% ± 1%65% ± 7%1.9–4.5 GBq>99%
  • * Radiochemical conversion (mean ± SD, n = 3–5) was estimated from LC-radio-MS analysis of crude reaction mixture.

  • Radiochemical yield (mean ± SD, n = 3–5) is based on amount of isolated radioactivity after purification and relative to amount of 11C-methyl iodide initially trapped in reactor.

  • Isolated radioactivity amount of purified product (n = 3–5).

  • Radiochemical purity was determined by LC-radio-MS analysis of final product formulation (n = 3–5).