TABLE 2

Results of Patients Not Receiving Therapeutic Dose Because of Altered Biodistribution

Assessment by treatment siteAssessment by independent review
Patient no.Biodistribution by visual inspection of γ imagesTBRT (h)Visual assessment of γ-camera imagesBiodistribution result
1Unknown*45Day 0: Most activity in blood pool, and uptake in normal liver and spleen less than in heartAltered
Day 4: Blood pool not visualized; diffuse, increased uptake in liver and spleen
Day 7: Altered biodistribution best appreciated by comparison of 3 image sets
2Altered by lung uptake154Day 0: Most activity in blood pool; uptake in normal liver and spleen less than in heartExpected
Day 2: Most activity in blood pool; uptake in normal liver and spleen less than in heart
Day 6: Most activity in blood pool; uptake in normal liver and spleen less than in heart; normal biodistribution best visualized on day 0
3Altered by lung uptake101Day 0: Most activity in blood pool; uptake in normal liver and spleen less than in heartExpected
Day 3: Most activity in blood pool; uptake in normal liver and spleen less than in heart; tumor targeting
Day 6: Most activity in blood pool; uptake in normal liver and spleen less than in heart; tumor targeting; normal biodistribution best visualized on day 3
4Altered by stomach uptakeNRNA
5Altered by lung uptakeNRNA
  • * Deemed to have altered biodistribution because of TBRT of 45 h.

  • NR = not reported; NA = not available.