TABLE 2

Kinetic Rate Constants and VTs of 18F-MCL-524

1TCM2TCMGA
RegionSubjectK1 (mL·cm−3·min−1)k2 (min−1)SSRAICVT (mL·cm−3)SSRAICVT (mL·cm−3)VT (mL·cm−3)
StriatumM10.26 (0.9)0.015 (2.0)791−1417.1 (1.6)793−917.2 (2.4)15.8 (0.23)
M20.30 (1.7)0.020 (3.2)1,3882414.9 (2.3)1,3692914.9 (3.1)14.7 (0.29)
M30.22 (1.4)0.012 (3.1)460817.4 (2.3)4741417.4 (2.5)15.6 (0.38)
Mean0.26 (1.3)0.016 (2.7)880616.5 (2.0)8791116.5 (2.7)15.4 (0.30)
CerebellumM10.21 (0.9)0.044 (1.8)247−114.8 (1.3)239−7NA4.8 (0.40)
M20.29 (1.9)0.067 (4.6)1,490634.4 (4.4)1,501684.3 (4.4)4.7 (0.70)
M30.23 (0.7)0.039 (1.4)89−185.8 (1.2)89−135.8 (2.2)5.6 (0.29)
Mean0.24 (1.2)0.050 (2.6)609115.0 (2.3)610165.0 (3.3)5.0 (0.46)
  • SSR = sum of squared residuals; AIC = Akaike information criterion; NA = not available (2TCM could not calculate reasonable VT).

  • SE coefficients of variation are presented between parentheses.