TABLE 1

123I BZA2 SPECT Acquisition Parameters According to Hospital and Camera

HospitalCameraMatrix, number of steps, and step durationReconstruction methodSPECT/CT
Estaing UH/Jean Perrin CC, Clermont-FerrandAxis, Philips, 2 heads128, 60, 30 sFiltered backprojectionNo
Nord UH, Saint-EtienneHelix, Elscint, 2 heads128, 60, 34 sFiltered backprojectionYes
Purpan UH, ToulouseIrix, Philips, 3 heads128, 120, 30 sIterativeNo
Sainte-Marguerite UH, Marseillee.cam 2, Siemens, 2 heads128, 64, 30 sIterativeNo
Archet UH, NiceInfinia, GE, 2 heads128, 60, 30 sIterativeNo
Fournier UH, NancySymbia T2, Siemens, 2 heads128, 64, 30 sIterativeYes
Croix-Rousse UH, LyonSymbia T2, Siemens, 2 heads128, 64, 30 sIterativeYes
Trousseau UH, ToursSymbia T2, Siemens, 2 heads128, 60, 30 sIterativeYes
  • UH = University Hospital; CC = Comprehensive Cancer Center; GE = GE Healthcare.