TABLE 4

Receiver Operating Characteristic Curve Analysis of 18F-FDOPA PET Diagnostic Criteria for Differentiating RPBM from LDRI

Diagnostic criterionArea under curveConfidence intervalThreshold for RPBMSensitivity*Specificity*Positive predictive value*Negative predictive value*Accuracy*
SUVmax0.8220.732–0.913≥2.7468.8 (22/32)68.6 (35/51)57.9 (22/38)77.8 (35/45)68.7
SUVmean0.8220.733–0.911≥2.368.8 (22/32)70.6 (36/51)59.5 (22/37)78.3 (36/46)69.9
L/Smax0.8370.753–0.921≥0.8675.0 (24/32)72.5 (37/51)63.2 (24/38)82.2 (37/45)73.5
L/Smean0.8230.736–0.910≥0.9568.8 (22/32)76.5 (39/51)64.7 (22/34)79.6 (39/49)73.5
L/Nmax0.8370.753–0.922≥2.0281.3 (26/32)72.5 (37/51)65.0 (26/40)86.0 (37/43)75.9
L/Nmean0.8290.743–0.916≥1.7081.3 (26/32)72.5 (37/51)65.0 (26/40)86.0 (37/43)75.9
Visual scale0.8920.824–0.960≥281.3 (26/32)84.3 (43/51)76.5 (26/34)87.8 (43/49)83.1
  • * Reported as percentage.