TABLE 2

Binding Values and Percentage Change of 11C-PIB According to Analytic Method

MethodADMCIControlAll
RPM2 (BPND + 1)
 Baseline1.87 ± 0.101.39 ± 0.391.12 ± 0.271.40 ± 0.41
 Follow-up1.86 ± 0.131.46 ± 0.391.15 ± 0.291.44 ± 0.41
 Percentage change−0.3 ± 5.95.5 ± 7.4*1.9 ± 3.22.7 ± 6.0*
Logan DVR
 Baseline1.70 ± 0.081.31 ± 0.321.08 ± 0.231.32 ± 0.34
 Follow-up1.68 ± 0.101.37 ± 0.321.11 ± 0.241.35 ± 0.33
 Percentage change−1.0 ± 5.25.3 ± 6.02.1 ± 3.5*2.6 ± 5.4
SUVr60–90
 Baseline2.16 ± 0.091.57 ± 0.521.26 ± 0.381.59 ± 0.52
 Follow-up2.07 ± 0.221.67 ± 0.501.29 ± 0.351.62 ± 0.49
 Percentage change−4.3 ± 8.68.0 ± 9.22.6 ± 4.22.9 ± 8.7
SUVr40–60
 Baseline2.02 ± 0.101.54 ± 0.461.21 ± 0.321.53 ± 0.46
 Follow-up2.02 ± 0.191.62 ± 0.461.28 ± 0.351.59 ± 0.46
 Percentage change0.1 ± 6.45.5 ± 7.4*5.8 ± 6.14.3 ± 6.9
  • Level of significance for percentage change and for differences between baseline and follow-up values: *P = 0.06; P = 0.07; P < 0.05.