TABLE 7

18F-FDG Cardiac PET Acquisition Parameters

ParameterRecommendation
Tracer dose185–370 MBq (5–10 mCi), 3-dimensional mode
370–555 MBq (10–15 mCi), 2-dimensional mode
Delay after injection45–60 min (nondiabetic patients)
60–90 min (diabetic patients)
Patient positioningSupine (arms-up preferred)
Imaging mode2-dimensional or 3-dimensional; list, gated, or static
Image duration10–30 min (depending on counting rate and dose)
Attenuation correctionBefore or immediately after emission scan using radionuclide or CT transmission imaging
Reconstruction methodFiltered backprojection or ordered-subsets expectation maximization (iterative reconstruction)
Reconstructed pixel size2–5 mm
  • Adapted with permission from (6).