TABLE 1

Sensitivity, Specificity, and Likelihood Ratios of V/Q SPECT According to Criteria Tested

SPECT criteriaSensitivitySpecificityPositive likelihood ratioNegative likelihood ratio
1 segmental or subsegmental mismatch0.92 (0.84–1)0.84 (0.79–0.89)5.7 (4.1–8)0.10 (0.04–0.25)
≥1 segmental mismatch0.86 (0.76–0.96)0.93 (0.89–0.96)11.4 (6.9–18.8)0.15 (0.08–0.31)
≥2 segmental or subsegmental mismatches0.88 (0.79–0.97)0.95 (0.91–0.98)16.0 (8.9–28.6)0.13 (0.06–0.27)
≥1 segmental or 2 subsegmental mismatches0.92 (0.84–1)0.91 (0.87–0.95)10.2 (6.5–16)0.09 (0.04–0.23)
>1 segmental mismatch0.82 (0.71–0.93)0.96 (0.93–0.99)20.4 (10.2–40.7)0.19 (0.11–0.35)
≥2 segmental mismatches0.63 (0.51–0.78)0.97 (0.95–1)25.3 (10.4–61.7)0.38 (0.26–0.54)
≥3 segmental or subsegmental mismatches0.67 (0.55–0.82)0.99 (0.97–1)44.9 (14.4–140.4)0.33 (0.22–0.50)
  • Data in parentheses are 95% confidence intervals.