TABLE 1

Binding Potential Results for 123I-Ioflupane Imaging

Binding potential (mean ± SD) in:
ScanAnesthetized miceAwake miceR (%)Mean R (%)
1 (15–40 min)32.8
 Left2.43 ± 1.020.68 ± 0.2928.0
 Right2.21 ± 1.070.83 ± 0.5337.6
2 (45–70 min)49.6
 Left2.12 ± 0.410.97 ± 0.1845.8
 Right2.00 ± 0.601.07 ± 0.2953.5
  • R = ratio of binding potential in awake mice to that in anesthetized mice.