TABLE 3

Selected Organ Dose and ED for Discussed Radiopharmaceuticals

Organ68Ga-DOTATATE*68Ga-DOTATOC (12)68Ga-DOTANOC (13)111In-DTPA-octreotide (19)18F-FDG (20)
Kidneys (mSv/MBq)9.21E−022.2E−018.97E−024.5E−011.7E−02
Liver (mSv/MBq)4.50E−027.4E−023.38E−027.0E−022.1E−02
Spleen (mSv/MBq)2.82E−012.4E−017.25E−023.2E−011.1E−02
Urinary bladder wall (mSv/MBq)1.25E−017.0E−028.36E−021.8E−011.3E−01
ED (mSv/MBq)2.57E−022.3E−021.67E−028.0E−021.9E−02
Typical IA
 MBq18518518574370
 mCi555210
Estimated ED per scan (mSv)4.84.33.15.97.0
  • * Radiation dose to uroepithelium is higher than would be experienced in patients allowed to void after injection.

  • There are technical differences between these reported series. Additionally, subjects in these series are not same.

  • IA = injected activity for adult scan.