TABLE 2

Comparison of β-Amyloid Binding and Blood Flow Parameters Between β-Amyloid–Positive AD (n = 8) and –Negative HC (n = 9) Groups

Mean values of 4 cortical regions*
ParameterADHCCohen dP
2TCM
Embedded Image (mL⋅cm−3⋅min−1)0.195 ± 0.0190.246 ± 0.037NA0.003
Embedded Image (mL⋅cm−3)10.62 ± 2.576.84 ± 1.07NA0.001
Embedded Image (mL⋅cm−3⋅min−1)0.252 ± 0.0180.281 ± 0.070NA0.28
Embedded Image (mL⋅cm−3)6.05 ± 1.245.45 ± 1.13NA0.32
Embedded Image (mL⋅cm−3)4.57 ± 1.441.38 ± 0.473.25<0.0001
DVR (2TCM)1.75 ± 0.131.27 ± 0.114.22<0.0001
Reference tissue models
 DVR (MRTM)1.54 ± 0.0671.18 ± 0.114.03<0.0001
 SUVR1.79 ± 0.141.30 ± 0.124.03<0.0001
  • * Frontal, lateral temporal, parietal, and posterior cingulate cortices.

  • NA = not applicable.

  • Data are expressed as mean ± SD. Effect size in group comparison was determined by Cohen d, and P values were calculated by Student t test (2-tailed, unpaired).