TABLE 5.

Comparison of Multiple Uptake Parameters at Multiple Imaging Time Points in Patients with Prostate Cancer

Imaging time point
Parameter12345
Time (min)12.9 ± 2.835.3 ± 3.757.9 ± 4.7123.6 ± 7.2184.8 ± 9.8
Interval (min)22.4022.6065.7061.20
Global
 SUV10mean (log-scale)2.732.772.752.692.6
  Mean difference (log-scale)0.04<0.01−0.03−0.02
  Percentage change/min*0.3<0.1−0.1<0.01
  P0.00160.77080.11540.1832
 SUV10act5.86.596.67.357.64
  Mean difference (log-scale)0.790.410.850.51
  Percentage change/min*5.31.41.40.9
  P<0.0001<0.0001<0.0001<0.0001
Malignant
 mSUV10max3.633.843.934.1
  Mean difference (log-scale)0.240.090.24
  Percentage change/min (log-scale)1.60.30.4
  P<0.0001<0.0001<0.0001
 mSUV10mean2.852.9433.02
  Mean difference (log-scale)0.110.060.05
  Percentage change/min*0.70.20.1
  P<0.0001<0.00010.0365
 mSUV10act6.947.27.417.34
  Mean difference (log-scale)0.440.20.43
  Percentage change/min*30.70.7
  P<0.0001<0.0001<0.0001
Normalized
 mSUV10max:bkg
  Mean difference (log-scale)0.080.010.04
  Percentage change/min*0.5<0.10.1
  P0.03860.83620.4001
 mSUV10act:bkg
  Mean difference (log-scale)0.280.110.22
  Percentage change/min*1.90.40.4
  P00.00040.0032
  • * Percentage change per minute values is identical for both log and original scales.

  • Time interval between time points 3 and 4 and 4 and 5 is approximately 3 times that of 1–2 and 2–3. SUV10mean and SUV10act represent mean SUV and total 18F-NaF activity of VOI containing all bone with SUV ≥10, respectively.