TABLE 5

S factors (mGy/MBq) for 125I

Source
Target123456789
10.0012420.0002620.0001160.0001030.0001010.0001010.0001000.0001000.000101
20.0002880.0015890.0002940.0001090.0001020.0001020.0001010.0001010.000100
30.0001180.0002950.0014540.0002280.0001030.0001020.0001010.0001000.000100
40.0001020.0001090.0002270.0011930.0002010.0001030.0001020.0001020.000100
50.0001020.0001030.0001040.0002010.0013910.0003060.0001260.0001050.000102
60.0001000.0001000.0001030.0001020.0003040.0026800.0005220.0001730.000105
70.0000990.0001000.0001020.0001010.0001280.0005210.0029730.0006950.000137
80.0000990.0000990.0001010.0001010.0001050.0001730.0006900.0044080.000285
90.0001000.0001000.0001000.0001010.0001020.0001050.0001390.0002870.001233
  • Target and source numbers correspond to different cell layers of testis model as described in Figure 1.