Imaging interval (min from dose) | Scan type | Location | Acquisition time per bed position (min)* |
−20 (before dosing) | Transmission | Head to mid thigh | 2 |
0–10† | Dynamic emission | Upper chest | 10 s (repeated) |
10–30 | Emission | Head to mid thigh | 2 |
30–50 | Emission | Head to mid thigh | 2 |
50–70 | Emission | Head to midthigh | 2 |
70–100 | Break | — | — |
100–120 | Transmission | Head to mid thigh | 2 |
120–150 | Emission | Head to mid thigh | 3 |
150–180 | Emission | Head to mid thigh | 3 |
180–210 | Break | — | — |
210–230 | Transmission | Head to midthigh | 2 |
230–270 | Emission | Head to mid thigh | 5 |
270–310 | Emission | Head to mid thigh | 5 |
* All head–to–mid thigh transmission and emission scans incorporated 7 bed positions.
† Zero time (T0) is time of BMS747158 dose administration.