TABLE 4

Number of Positive 111In-DTPA-Octreotide Scintigraphy and 68Ga-DOTATATE PET Results in Patients with Different Histologic Grades of Disease

Number of patients with disease on…
Histologic tumor gradeTotal patientsCross-sectional imaging111In-DTPA-octreotide scintigraphy68Ga-DOTATATE PETP*
Low282411 (45.8%)22 (91.7%)<0.001
Intermediate19193 (15.8%)16 (84.2%)<0.001
High442 (50%)3 (75%)NS
Total51471641<0.001
  • * Comparison of number of patients with positive disease identified using 111In-DTPA-octreotide scintigraphy and 68Ga-DOTATATE PET for different histologic grades of tumor. P > 0.05 was regarded as nonsignificant (NS).

  • Positive for 111In-DTPA-octreotide scintigraphy means weak or equivocal uptake (Krenning score < 2). Krenning score scale: 0 = no abnormality, 1 = faint uptake in tumor; 2 = clear uptake in tumor but less than in liver; 3 = uptake greater in tumor than in liver; 4 = accumulation much greater in tumor than in liver (18).