TABLE 1

Patient Characteristics and Results

Findings
Type of malignancynAge (y)Injected dose (MBq)Planar imagesSPECT/CTSurgeryIntraoperative localizationPostoperative coursePathology
Prostate cancer8Median: 68; range: 56–71Median: 205; range: 147–2398 midabdominal SNs; 16 pelvic or presacral SNs8 SNs around aortic bifurcation (exact localization); localization of 20 other SNsLaparoscopic sentinel lymphadenectomyDetection and localization of all SNs with portable γ-camera and probeUncomplicated: 7 pts; lymphocele: 1 ptParaaortic SN positive: 1 pt; parailiac SN positive: 2 pts
Renal cell carcinoma6Median: 54; range: 45–59Median: 224; range: 95–2434 midabdominal SNs; 1 parasternal SN; nonvis: 2 pts8 para- and interaortocaval SNs (exact localization); 1 parasternal SNLaparoscopic nephrectomy and sentinel lymphadenectomy: 1 pt; open procedure: 5 ptsVisualization of SN with portable γ-camera: 3 pts; detection possible only with γ-probe: 3 pts; detection of additional hot node in 1 pt*Uncomplicated: 4 pts; infected wound: 1 pt; cicatricial hernia of nephrectomy wound:1 ptAll SNs negative
Testicular cancer4Median: 32; range: 31–40Median: 77; range: 59–977 midabdominal SNs5 interaortocaval SNs; 2 left paraaortic SNs; 1 SN along testicular vein (exact localization); localization of 1 parailiac SNLaparoscopic sentinel lymphadenectomyDetection and localization of all SNs with portable γ-camera and probeUncomplicated: 3 pts; hydronephrosis:1 ptAll SNs negative
  • * Two paraaortic sentinel nodes were found and removed during surgery, whereas preoperative SPECT/CT had visualized only 1 paraaortic sentinel node.

  • Nonvis = nonvisualization; Pt = patient; SN = sentinel node.