TABLE 3.

18F-FDG PET Characteristics in 19 Studies Reviewed

StudyScannerScan mode18F-FDG dose (MBq)Interval between 18F-FDG injection and PET (min)Interval between end induction therapy and posttreatment PET (d)Interval between posttreatment PET and surgery (d)Image reconstruction
Schulte et al. (5)ECAT 931-08-12Partial120–30045–6012–18Not mentionedMultiplicative iterative (29)
Franzius et al. (6)ECAT EXACT 921/47Whole body3.7/kg60Not mentioned3–28 (mean, 21)Filtered backprojection, Hanning filter, cutoff at Nyquist frequency
Smith et al. (7)ECAT EXACT 31Partial1850–60*, 60–70Not mentionedNot mentionedFiltered backprojection, Hanning filter, cutoff at Nyquist frequency
Nair et al. (8)ECAT EXACT 47Whole body3704514Few daysWhole-body format, Hanning filter, cutoff at cutoff frequency = 0.35 of Nyquist frequency
Brücher et al. (9)ECAT 951/RPartial250–2704021<7Filtered backprojection, Hanning filter, cutoff at 0.4 cycles/pixel
ECAT EXACT
Ryu et al. (10)ScanditronixPartial3704514Not mentionedFiltered backprojection to in-plane resolution of 7 mm in full width at half maximum
Kitagawa et al. (11)AdvancePartial244–48840>28Not mentionedNot mentioned
Brink et al. (12)ECAT EXACT 922 (+)Whole body5/kg90Not mentionedNot mentionedIterative, ordered-subset expectation maximization, segmented attenuation correction
Chen et al. (13)AdvancePartial259–40760Not mentionedNot mentionedCorrections of data for random and scattered coincidences and attenuation; Hanning filter
Wieder et al. (14)ECAT EXACTPartial300–4006021–28< 7Iterative, ordered-subset expectation maximization (8 iterations, 4 subsets), postreconstruction smoothing with 4-mm Gaussian filter
Song et al. (15)ECAT HR+ 2DWhole body5556021–28Just beforeNot mentioned
Cascini et al. (16)ECAT EXACT 47Whole body300–38560Not mentionedFew daysIterative, ordered-subset expectation maximization (2 iterations, 16 subsets)
Huang et al. (17)ECAT EXACTPartial259–370457Not mentionedNot mentioned
Wieder et al. (18)ECAT EXACTPartial300–4004021–2821–28Iterative, ordered-subset expectation maximization (8 iterations, 4 subsets), and then smoothed in 3 dimensions using 4-mm Gaussian filter
Iagaru et al. (19)ECAT EXACT 953AWhole body550457–36 (mean ± SD, 16 ± 9)Not mentionedNot mentioned
Biograph LSO PET/CT60
Nishiyama et al. (20)ECAT EXACT HR+Whole body185–2006012 (range, 2–24)Not mentioned (32 [range, 19–40] between chemotherapy and surgery)Iterative, ordered-subset expectation maximization (2 iterations, 8 subsets)
Benz et al. (21)Biograph DuoWhole body7.77/kg77 ± 8.7Not mentionedNot mentionedIterative, ordered-subset expectation maximization (2 iterations, 8 subsets), postreconstruction gaussian filter; final image resolution of 8.8 mm in full width at half maximum
Smithers et al. (22)Philips Allegro GSOWhole body210–4274524–32Chemotherapy, 4Iterative, 3-dimensional row-action maximum-likelihood algorithm
Chemoradiotherapy, 4.5
Ye et al. (23)SHR-22000Partial370604–14 (median, 8)2–22 (median, 12)Hanning filter, cutoff at Nyquist frequency
  • * Dynamic scan protocol, followed by static emission.

  • No information on which scanner individual patients were scanned.

  • Each patient baseline and repeated PET scan obtained on same scanner.