TABLE 7

Dosimetry Associated with Weight-Based Approach to PET/CT Scan Acquired for Anatomic Correlation

PET acquisitionEffective dose (mSv)
Patient categoryPatient weight (kg)CT acquisition (maximum mAs)Injected activity (MBq)Time per FOV (min)CTPETTotal
Color
 Pink6–7.4103732.35.07.3
 Red7.5–9.4104532.15.17.2
 Purple9.5–11.4155533.05.18.1
 Yellow11.5–14.4206833.85.59.3
 White14.5–18.4208733.65.59.1
 Blue18.5–22.42010833.45.38.7
 Orange22.5–31.42514254.06.09.9
 Green31.5–40.53019054.66.611.1
 Black40.5–553025254.17.511.6
Size
 Small adult55–703533054.37.611.9
 Large adult>704037054.37.011.3
  • Color category in table is based on patient's weight. Maximum milliampere-seconds, injected activity, and scanning time per bed position (field of view [FOV]) are determined based on weight classification. Also listed are effective doses for CT, PET, and total PET/CT scan (28).