TABLE 3

Plasma Input Parametric Image Data

Pharmacokinetic parameterHRRT reconstruction methodUnfixed interceptFixed intercept to origin
SlopeInterceptrSloper
Logan VT3D-FBP0.83 ± 0.130.78 ± 0.540.94 ± 0.030.99 ± 0.120.91 ± 0.08
3D-FBP G61.03 ± 0.050.21 ± 0.400.98 ± 0.001.07 ± 0.110.98 ± 0.01
3D-OSWLS1.04 ± 0.070.17 ± 0.380.97 ± 0.011.07 ± 0.110.97 ± 0.01
3D-OSWLS G60.98 ± 0.060.15 ± 0.300.99 ± 0.001.01 ± 0.100.98 ± 0.00
BFM VT3D-FBP1.00 ± 0.141.44 ± 0.800.96 ± 0.011.29 ± 0.200.89 ± 0.12
3D-FBP G61.05 ± 0.110.18 ± 0.410.98 ± 0.011.09 ± 0.150.98 ± 0.01
3D-OSWLS1.10 ± 0.120.29 ± 0.410.97 ± 0.011.16 ± 0.140.97 ± 0.01
3D-OSWLS G60.98 ± 0.060.11 ± 0.320.98 ± 0.001.00 ± 0.100.98 ± 0.00
  • G6 = 6-mm FWHM gaussian kernel.

  • Slope, intercept, and r (all data are mean ± SD) of plasma input kinetic data using HRRT- vs. HR+-reconstructed scans of 5 subjects, over various ROIs.