TABLE 4

Comparison of 4FMFES Radiation Dosimetry Estimates Between Subjects with Intact Gallbladder, Using Various Gallbladder Models, and Subjects with Prior Cholecystectomy

Subjects with intact gallbladder (n = 8)
OrganNo gallbladder modelGallbladder-voiding model*Simulated cholecystectomySubjects with prior cholecystectomy (n = 2)
Absorbed dose (mGy/MBq ± SD)
 Adrenals0.020 ± 0.0020.019 ± 0.0010.016 ± 0.0010.016 ± 0.001
 Gallbladder wall0.988 ± 0.3480.709 ± 0.247
 Lower large intestine0.038 ± 0.0100.046 ± 0.0070.066 ± 0.0040.063 ± 0.009
 Small intestine0.104 ± 0.0270.127 ± 0.0200.184 ± 0.0140.173 ± 0.028
 Upper large intestine0.117 ± 0.0280.141 ± 0.0200.200 ± 0.0150.187 ± 0.031
 Ovaries0.025 ± 0.0040.029 ± 0.0030.038 ± 0.0020.037 ± 0.004
 Pancreas0.026 ± 0.0030.024 ± 0.0020.018 ± 0.0000.017 ± 0.001
 Uterus0.024 ± 0.0040.027 ± 0.0030.033 ± 0.0040.034 ± 0.006
Effective dose (mSv/MBq ± SD)0.025 ± 0.0030.027 ± 0.0020.033 ± 0.0010.031 ± 0.002
  • * Gallbladder-voiding model: 50% of gallbladder activity was transferred to intestines every 3 h.

  • Simulated cholecystectomy: total gallbladder activity was transferred to intestines.

  • For all other organs, absorbed dose varied by less than 12% when either gallbladder model was applied.