TABLE 4

Characteristics of Patients Who Had False-Positive S-TPD Corrected by MF-TPD for Detection of ≥70% Stenosis

Patient no.Age (y)SexBMIStress ejection fraction (%)S-TPD (%)MF-TPD (%)
162Male336473
288Male353363
3*68Female337683
466Female406063
556Male364164
660Male3459104
776Male325674
  • * True-positive for S-TPD for detection of ≥50% stenosis.