TABLE 4

Comparison of Ki Estimates from Measured and Estimated Input Functions from Mouse Data (n = 17)

Input function typeStatistics of Ki*MyocardiumBrainMuscle
MeasuredEstimate (1/min)0.1381 ± 0.06550.0291 ± 0.01700.0112 ± 0.0082
IDIF, no correctionEstimate (1/min)0.0039 ± 0.0041<10−5<10−5
Error (%)−94.8 ± 7.3−99.9 ± 0.00−99.7 ± 1.11
Corr. coefficient−0.664−0.3360.191
t test P value<10−5<10−53.7 × 10−5
MCIF, 0-sampleEstimate (1/min)0.1321 ± 0.06960.0225 ± 0.01220.0092 ± 0.0063
Error (%)−3.0 ± 21.7−13.3 ± 31.5−7.8 ± 29.3
Corr. coefficient0.8690.8430.945
t test P value0.4870.0110.016
MCIF, 1-sampleEstimate (1/min)0.1414 ± 0.07850.0268 ± 0.01680.0106 ± 0.0076
Error (%)−1.7 ± 21.8−8.2 ± 17.51.6 ± 28.0
Corr. coefficient0.9240.9110.969
t test P value0.6690.2000.289
  • * Estimate (1/min) and error (%) are expressed as mean ± SD.

  • Corr. coefficient = correlation coefficient.