TABLE 1

Kinetic Parameters for 18F-FLT PET in Mice Implanted with A431 and LLC Tumors

Cell lineMethodK1K1/k2k3k4VbDVmKFLT
A431 (n = 7)3C5P0.227 (24.6)1.860 (51.5)0.123 (32.4)0.011 (27.6)0.033 (58.5)20.64 (46.6)0.103 (14.2)
3C4P0.163 (17.0)6.349 (35.2)0.021 (38.7)0.055 (60.2)0.068 (18.1)
2C3P0.134 (14.4)17.52 (34.7)0.087 (57.7)
GPGA0.076 (15.6)
LLC (n = 10)3C5P0.169 (26.9)0.656 (14.2)0.017 (29.3)0.015 (22.1)0.044 (45.6)0.793 (39.9)0.010 (20.3)
3C4P0.133 (28.5)0.788 (9.4)0.006 (30.3)0.059 (39.0)0.005 (34.2)
2C3P0.063 (24.5)1.156 (17.7)0.093 (15.9)
GPGA0.003 (34.9)
  • 3C5P = 3 compartments and 5 parameters (K1, K1/k2, k3, k4, and Vb); 3C4P = 3 compartments and 4 parameters (K1, K1/k2, k3, and Vb), with k4 fixed at zero; 2C3P = 2 compartments and 3 parameters (K1, K1/k2, and Vb); GPGA = Gjedde–Patlak graphic analysis.

  • Data are presented as means (CVs).