TABLE 3

Patients with Both Helical and Cine CT PET

PET/CT scanSeverity (% of maximum)Size–severity (% <60% maximum)% of LV <2.0 SD% LV <2.5 SDTransaxial misregistration (mm)Mean Δ cine vs. helical (mm)Diaphragm mm to CT 0Mean Δ mm diaphragm
All helical CT PET74.2 ± 7.38.5 ± 17.58.2 ± 5.86.1 ± 5.68.34 ± 6.514.45.2 ± 15.83.3
All cine CT PET77.6 ± 6.24.5 ± 11.65.1 ± 5.13.5 ± 4.73.93 ± 3.502.0 ± 15.4
n = 114, P for Δ0.00000.00240.00000.00000.00000.0002
Helical CT PET with artifacts73.7 ± 7.37.5 ± 17.68.7 ± 5.46.3 ± 5.311.87 ± 5.897.25.3 ± 16.92.6
Cine CT PET same patients79.2 ± 5.01.2 ± 3.33.9 ± 3.82.2 ± 3.04.69 ± 3.672.7 ± 16.2
n = 67, P for Δ0.00000.00380.00000.00000.00000.0334
  • LV = left ventricle.

  • Quantitative measurements of defects are for quadrant containing misregistration artifactual defect or for worst quadrant in absence of misregistration artifact.