TABLE 2

P Values for PPV, Sensitivity, and AUC for Comparisons of Early and Delayed Planar, SPECT, and SPECT/CT Imaging Methods

P
Imaging methodPPVSensitivityAUC
Planar E vs. planar D0.090.0450.014
Planar E/D vs. planar E or planar DNS<0.00010.002
SPECT E vs. SPECT DNSNSNS
SPECT E/D vs. SPECT E or SPECT DNS0.0560.045
SPECT E vs. planar ENS<0.0001<0.0001
SPECT D vs. planar DNS0.0560.023
SPECT E or SPECT D vs. planar E/DNSNSNS
SPECT E/D vs. planar E/DNSNSNS
SPECT/CT E vs. SPECT/CT D0.0270.0760.036
SPECT/CT E/D vs. SPECT/CT ENS0.0030.001
SPECT/CT E/D vs. SPECT/CT D0.001<0.0001<0.0001
SPECT/CT E/D vs. SPECT/CT E/SPECT DNSNSNS
SPECT/CT E/D vs. SPECT/CT E/planar DNSNSNS
SPECT/CT E or SPECT/CT D vs. planar E/DNSNSNS
SPECT/CT E/D vs. planar E/D0.05<0.0001<0.0001
SPECT/CT E/planar D vs. planar E/DNS<0.0001<0.0001
SPECT/CT E vs. SPECT ENSNS0.049
SPECT/CT E/D vs. SPECT E/DNS0.0110.004
SPECT/CT E/SPECT D vs. SPECT E/D0.0110.0030.001
  • E = early; D = delayed; E/D = early and delayed; NS = not statistically significant.