TABLE 1

Characteristics of Experimental Animals at Baseline

CharacteristicGroup 1: balloon occlusionGroup 2: single bolusP
Pig body mass (kg)42.1 ± 0.241.7 ± 0.5NS
Ejection fraction (%)46.6 ± 4.244.9 ± 5.1NS
Left ventricular mass (g)89.1 ± 6.186.5 ± 5.3NS
Infarct size (g)14.5 ± 2.917.8 ± 1.9NS
Infarct size (% of LV mass)16.3 ± 3.420.6 ± 2.7NS
End-diastolic volume (mL)64.2 ± 2.967.3 ± 5.2NS
End-systolic volume (mL)35.2 ± 5.833.8 ± 4.9NS
Cardiac output (L/min)2.9 ± 0.12.7 ± 0.5NS
Stroke volume (mL)28.7 ± 2.325.5 ± 2.2NS
  • P value denotes comparison of mean baseline values in balloon-occlusion delivery group with mean baseline values in single-bolus delivery group using ANOVA.